This is the genuine OEM defrost control board (part #1173636) for the Tempstar T2H336GKD100 heat pump. The defrost board is the brain of the outdoor unit during heating: it monitors coil temperature and run time, then commands a defrost cycle to melt frost from the outdoor coil by reversing the system and shutting off the condenser fan. It also coordinates the reversing valve, compressor, and auxiliary heat. When the board fails, the heat pump may ice over and lose heating capacity, run defrost too often or never, leave the fan running during defrost, or fail to switch between heating and cooling. A faulty defrost board often mimics refrigerant or sensor problems, so accurate diagnosis saves time and money.

Specifications

Spec Value
Part Number 1173636
Type Defrost Control Board
Brand Tempstar (ICP / Heil / Comfortmaker family)
Control Voltage 24V
Application Heat pump outdoor unit defrost control
Fitment OEM

Compatibility

Built as the factory replacement for the Tempstar T2H336GKD100 heat pump. Because the ICP family shares control electronics, this defrost board frequently fits comparable Heil, Comfortmaker, and ICP heat pumps. Match the part number and connector layout to your existing board before installing.

Installation Guide

  1. Safety First — Disconnect power at the disconnect and breaker, then verify zero voltage with a multimeter.
  2. Access — Remove the outdoor unit control panel cover.
  3. Document — Photograph every connector, the defrost sensor lead, and the timing/jumper settings before disconnecting.
  4. Remove — Unplug each harness, release the standoffs or screws, and lift out the old board.
  5. Install — Mount the new board, set defrost timing jumpers to match, and reconnect every harness per your photo.
  6. Test — Restore power, initiate a forced defrost, and confirm the reversing valve, compressor, and fan respond correctly.

Signs You Need a Replacement

  • Outdoor coil ices over and heating capacity drops
  • Defrost cycle runs constantly or never initiates
  • Fan runs during defrost or stays off when it shouldn't
  • No response from the reversing valve or compressor on a call

Shipping & Returns

Ships same day before 3 PM CST. 30-day returns. Backed by the National HVAC Parts fitment guarantee.

Shipping Information

  • Orders placed before 3PM CST ship same business day
  • Standard delivery: 2-5 business days
  • Express shipping available at checkout
  • Free shipping on orders over $75
  • Tracking number emailed upon shipment

Return Policy

  • 30-day returns on unused parts in original packaging
  • Electrical parts (capacitors, contactors, control boards) are final sale once installed
  • Email info@nationalhvacparts.com to initiate a return
  • Refunds processed within 5-7 business days

Frequently Asked Questions

Does this Control Board fit my Tempstar T2H336GKD100 — Heat Pump | Ships Today?
Yes. This is the factory-specified OEM control board for the Tempstar T2H336GKD100 — Heat Pump | Ships Today. It is a direct drop-in replacement that fits without modification. Always verify the model number on your equipment nameplate before ordering.
How do I replace the control board on my Tempstar T2H336GKD100 — Heat Pump | Ships Today?
Difficulty: Advanced (1–2 hrs)
Step 1: Turn off breaker. Step 2: PHOTOGRAPH all wire connections before touching anything. Step 3: Label each wire with tape. Step 4: Disconnect all wires, remove old board. Step 5: Mount new board, reconnect all wires matching your photo exactly. Step 6: Restore power and test all modes. Exact part number match is critical.
My HVAC system is completely dead. What could be wrong?
Completely dead HVAC (no LED on board) = failed control board or blown fuse. Check board fuse first (3A or 5A, costs $1–$5). If fuse is good and board has power but no LED, board is dead. Always photograph wiring before replacing.
Is this control board compatible with Bryant or Payne too?
Many Tempstar parts are cross-compatible with Bryant and Payne since all three brands are manufactured by Carrier Global Corporation. The same physical part is often used across brand labels with different model numbers. To verify: check your Bryant or Payne equipment service manual for cross-compatible part numbers, or email info@nationalhvacparts.com with your model number.
Should I use OEM or aftermarket for my Tempstar control board?
OEM essential. Control boards are model-specific with precise firmware and connector layouts. Aftermarket boards rarely match all functions and can cause intermittent failures or safety issues. Always match the exact OEM part number.