Same-day shipping before 3PM CST · 35,000+ OEM Parts · Texas CMBL & SAM.gov Registered · Government POs Accepted

Menu

Home Shop All Account Cart
Tempstar Defrost Control Board for T2H330GKA200 — Heat Pump OEM | Ships Today
Tempstar

Tempstar Defrost Control Board for T2H330GKA200 — Heat Pump OEM | Ships Today

SKU: 1173636-GEN Brand: Tempstar

OEM Guaranteed

Same-Day Ship

30-Day Returns

Secure Checkout

Texas CMBL #19328542014
SAM.gov Registered
Govt POs Accepted

Overview

This is a genuine OEM defrost control board (part number 1173636) for the Tempstar T2H330GKA200 heat pump. The defrost board is the brain of the outdoor unit during heating season — it monitors the coil temperature sensor and elapsed run time, then initiates a defrost cycle to melt frost off the outdoor coil. During defrost it commands the reversing valve, shuts off the condenser fan, and can energize auxiliary heat to keep supply air comfortable. A failed board leads to a frozen-over outdoor coil, poor heating performance, a unit that never defrosts (or defrosts constantly), or a heat pump that won't switch between heating and cooling. Replacing it restores correct defrost timing and full heat-pump efficiency.

Specifications

Spec Value
Part Number 1173636
Type Defrost Control Board
Brand Tempstar (ICP / Heil)
Control Voltage 24 VAC
Function Defrost timing, reversing valve and fan control

Compatibility

Designed as the factory replacement for the Tempstar T2H330GKA200 heat pump. The 1173636 defrost board is shared across numerous ICP-family heat pumps marketed as Tempstar, Heil, Comfortmaker, and Arcoaire. Match your old board's part number and connector layout before installing.

Installation Guide

  1. Safety First — Disconnect power at the disconnect and breaker, then verify zero voltage at the board with a multimeter.
  2. Access — Remove the condensing unit service panel to reach the control box.
  3. Document — Photograph every plug, wire, and the defrost-time jumper setting before disconnecting.
  4. Remove — Unplug each harness, release the standoffs or screws, and lift out the old board.
  5. Install — Mount the new board, reconnect every harness per your photos, and set the defrost-time selector to match the original.
  6. Test — Restore power, run a heating cycle, and confirm normal operation and that a forced defrost behaves correctly.

Signs You Need a Replacement

  • Outdoor coil ices over and never clears
  • Heat pump won't switch between heating and cooling modes
  • Unit defrosts too often or stays stuck in defrost
  • No output to the reversing valve or condenser fan during defrost

Shipping & Returns

Ships same day before 3 PM CST. 30-day returns. Backed by the National HVAC Parts fitment guarantee.

Shipping Information

  • Orders placed before 3PM CST ship same business day
  • Standard delivery: 2-5 business days
  • Express shipping available at checkout
  • Free shipping on orders over $75
  • Tracking number emailed upon shipment

Return Policy

  • 30-day returns on unused parts in original packaging
  • Electrical parts (capacitors, contactors, control boards) are final sale once installed
  • Email info@nationalhvacparts.com to initiate a return
  • Refunds processed within 5-7 business days

Frequently Asked Questions

Does this Control Board fit my Tempstar T2H330GKA200 — Heat Pump OEM | Ships Today?
Yes. This is the factory-specified OEM control board for the Tempstar T2H330GKA200 — Heat Pump OEM | Ships Today. It is a direct drop-in replacement that fits without modification. Always verify the model number on your equipment nameplate before ordering.
How do I replace the control board on my Tempstar T2H330GKA200 — Heat Pump OEM | Ships Today?
Difficulty: Advanced (1–2 hrs)
Step 1: Turn off breaker. Step 2: PHOTOGRAPH all wire connections before touching anything. Step 3: Label each wire with tape. Step 4: Disconnect all wires, remove old board. Step 5: Mount new board, reconnect all wires matching your photo exactly. Step 6: Restore power and test all modes. Exact part number match is critical.
My HVAC system is completely dead. What could be wrong?
Completely dead HVAC (no LED on board) = failed control board or blown fuse. Check board fuse first (3A or 5A, costs $1–$5). If fuse is good and board has power but no LED, board is dead. Always photograph wiring before replacing.
Is this control board compatible with Bryant or Payne too?
Many Tempstar parts are cross-compatible with Bryant and Payne since all three brands are manufactured by Carrier Global Corporation. The same physical part is often used across brand labels with different model numbers. To verify: check your Bryant or Payne equipment service manual for cross-compatible part numbers, or email info@nationalhvacparts.com with your model number.
Should I use OEM or aftermarket for my Tempstar control board?
OEM essential. Control boards are model-specific with precise firmware and connector layouts. Aftermarket boards rarely match all functions and can cause intermittent failures or safety issues. Always match the exact OEM part number.
How fast does National HVAC Parts ship?
Orders placed before 3:00 PM CST ship the same business day. Standard delivery is 2–5 business days anywhere in the continental United States. Express shipping available at checkout. We ship from Houston, TX to all 50 states. 30-day return policy on all parts.
Home Shop Search Account Cart
Fitment Guaranteed
MR
Mike Rivera
HVAC Parts Specialist — Online