This OEM single-pole contactor (part number 1172472) is the main switching relay for the Tempstar TSA648GKA100 condensing unit. Rated at 30 amps with a 24-volt control coil and an integrated shunt, it energizes the compressor and condenser fan motor whenever the thermostat calls for cooling. Contactors are a high-wear part: every cooling cycle arcs across the contacts, slowly pitting and eroding them. A worn or failed contactor shows up as a unit that won't start, a buzzing or chattering sound, contacts welded shut so the compressor never stops, or an outdoor fan that hums but won't turn.

Specifications

Spec Value
Part Number 1172472
Type Single-Pole (1P) Contactor with Shunt
Brand Tempstar (ICP / Heil)
Contact Rating 30 Amps
Coil Voltage 24 VAC
Poles 1
Fits Model TSA648GKA100

Compatibility

Factory replacement for the Tempstar TSA648GKA100 and shared across many ICP-family condensing units (Tempstar, Heil, Comfortmaker, and select Carrier/Bryant 1-pole applications). Confirm the existing contactor is a 1-pole, 30A, 24V-coil unit before installing.

Installation Guide

  1. Safety First — Disconnect power at the outdoor disconnect and breaker, then verify zero voltage with a multimeter.
  2. Access — Remove the condensing unit service panel.
  3. Document — Photograph all wire connections before disconnecting.
  4. Remove — Transfer or label line, load, and 24V coil wires one at a time, then unscrew the old contactor from the bracket.
  5. Install — Mount the new contactor and reconnect each wire to the matching terminal per your photo.
  6. Test — Restore power and verify the contactor pulls in and the compressor and fan start on a cooling call.

Signs You Need a Replacement

  • Unit won't start unless you press the contactor button manually
  • Loud buzzing, humming, or chattering at the contactor
  • Burned, pitted, or welded contacts
  • Compressor runs continuously and won't shut off

Shipping & Returns

Ships same day before 3 PM CST. 30-day returns. Backed by the National HVAC Parts fitment guarantee.

Shipping Information

  • Orders placed before 3PM CST ship same business day
  • Standard delivery: 2-5 business days
  • Express shipping available at checkout
  • Free shipping on orders over $75
  • Tracking number emailed upon shipment

Return Policy

  • 30-day returns on unused parts in original packaging
  • Electrical parts (capacitors, contactors, control boards) are final sale once installed
  • Email info@nationalhvacparts.com to initiate a return
  • Refunds processed within 5-7 business days

Frequently Asked Questions

Does this Contactor fit my Tempstar TSA648GKA100 — 1-Pole 30A 24V Coil | Ships Today?
Yes. This is the factory-specified OEM contactor for the Tempstar TSA648GKA100 — 1-Pole 30A 24V Coil | Ships Today. It is a direct drop-in replacement that fits without modification. Always verify the model number on your equipment nameplate before ordering.
How do I replace the contactor on my Tempstar TSA648GKA100 — 1-Pole 30A 24V Coil | Ships Today?
Difficulty: Medium (30–45 min)
Step 1: Turn off breaker. Step 2: Open condensing unit panel. Step 3: Photograph ALL wiring on the contactor. Step 4: Label each wire with tape. Step 5: Disconnect wires and remove old contactor. Step 6: Mount new contactor, reconnect wires matching your photo. Step 7: Restore power and test.
My AC clicks but the compressor won’t turn on. What’s wrong?
Clicking from the outdoor unit without the compressor starting = worn contactor. The contactor sends power to the compressor. When its contacts are pitted, it clicks but can’t make solid contact. Look for: visible pitting/burn marks on the contactor face, intermittent operation, or buzzing.
Is this contactor compatible with Bryant or Payne too?
Many Tempstar parts are cross-compatible with Bryant and Payne since all three brands are manufactured by Carrier Global Corporation. The same physical part is often used across brand labels with different model numbers. To verify: check your Bryant or Payne equipment service manual for cross-compatible part numbers, or email info@nationalhvacparts.com with your model number.
Should I use OEM or aftermarket for my Tempstar contactor?
OEM recommended for reliability and warranty compatibility. OEM parts match exact factory specifications for proper fit, performance, and safety. While aftermarket alternatives cost less upfront, the risk of improper fit and reduced lifespan usually makes OEM the better value long-term.
How fast does National HVAC Parts ship?
Orders placed before 3:00 PM CST ship the same business day. Standard delivery is 2–5 business days anywhere in the continental United States. Express shipping available at checkout. We ship from Houston, TX to all 50 states. 30-day return policy on all parts.