This OEM definite-purpose contactor (part number 1059574) is the 2-pole, 40-amp switch with a 24V coil used in the Tempstar TCH060AKA4 heat pump. The contactor is the electrically operated relay that powers the compressor and condenser fan motor whenever the thermostat calls for cooling or heating. Applying 24V to the coil pulls the contacts in and passes line voltage to the outdoor unit. Contactors wear out — contacts pit, burn, and weld from arcing, and coils fail open. Typical symptoms are an outdoor unit that won't start, a buzzing or chattering contactor, or a unit that runs nonstop because the contacts have welded closed.
| Spec | Value |
|---|---|
| Part Number | 1059574 |
| Type | Definite Purpose Contactor |
| Brand | Tempstar (ICP / Heil family) |
| Poles | 2-Pole |
| Contact Rating | 40 Amp |
| Coil Voltage | 24V AC |
| Fitment | OEM Replacement |
Designed for the Tempstar TCH060AKA4 heat pump and interchangeable across many ICP, Heil, Comfortmaker, and Tempstar condensing units using a 2-pole 40A 24V contactor. Verify pole count, amp rating, and coil voltage against your existing part before installing.
Ships same day before 3 PM CST. 30-day returns. Backed by the National HVAC Parts fitment guarantee.