This is a genuine OEM single-pole contactor (Part #1050699) for the Tempstar TCH018AKC3 condensing unit. The contactor is the electrically operated switch that energizes the compressor and condenser fan motor whenever the thermostat calls for cooling. When the 24V control signal energizes the coil, the contacts pull in and pass line voltage to the outdoor unit. This is a 1-pole, 25-amp device with a 24-volt holding coil. Contactors are one of the most common failure points in an air conditioner because the contacts arc and pit every time they open and close. A failed contactor is the leading cause of a unit that hums but won't start, or one where the outdoor fan and compressor refuse to run even though the thermostat is calling.

Specifications

Spec Value
Part Number 1050699
Type Definite Purpose Contactor, 1-Pole
Brand Tempstar (ICP / Heil)
Contact Rating 25 Amps
Coil Voltage 24 VAC
Poles 1
Fits Model TCH018AKC3

Compatibility

Engineered as a direct OEM replacement for the Tempstar TCH018AKC3 outdoor unit. The 1050699 contactor is also shared across many comparable ICP-family condensing units sold under the Heil, Comfortmaker, and Tempstar nameplates. Always confirm your existing contactor is a 1-pole, 25A, 24V coil device before ordering.

Installation Guide

  1. Safety First – Disconnect power at the outdoor disconnect and main breaker. Verify zero voltage at the contactor terminals with a multimeter.
  2. Access – Remove the condenser service panel to expose the control box.
  3. Document – Photograph every wire and terminal position before disconnecting anything.
  4. Remove – Label and disconnect the line, load, and 24V coil wires, then unscrew the old contactor from its mounting bracket.
  5. Install – Mount the new 1050699 contactor and reconnect each wire exactly per your photo.
  6. Test – Restore power and confirm the contacts pull in on a cooling call and the compressor/fan energize.

Signs You Need a Replacement

  • Outdoor unit hums but compressor and fan don't start.
  • Visible burnt, pitted, or welded contacts.
  • Chattering or buzzing from the contactor.
  • Contacts stuck closed so the unit won't shut off.

Shipping & Returns

Ships same day before 3 PM CST. 30-day returns. Backed by the National HVAC Parts fitment guarantee.

Shipping Information

  • Orders placed before 3PM CST ship same business day
  • Standard delivery: 2-5 business days
  • Express shipping available at checkout
  • Free shipping on orders over $75
  • Tracking number emailed upon shipment

Return Policy

  • 30-day returns on unused parts in original packaging
  • Electrical parts (capacitors, contactors, control boards) are final sale once installed
  • Email info@nationalhvacparts.com to initiate a return
  • Refunds processed within 5-7 business days

Frequently Asked Questions

Does this Contactor fit my Tempstar TCH018AKC3 – 1-Pole 25A 24V Coil | Ships Today?
Yes. This is the factory-specified OEM contactor for the Tempstar TCH018AKC3 – 1-Pole 25A 24V Coil | Ships Today. It is a direct drop-in replacement that fits without modification. Always verify the model number on your equipment nameplate before ordering.
How do I replace the contactor on my Tempstar TCH018AKC3 – 1-Pole 25A 24V Coil | Ships Today?
Difficulty: Medium (30–45 min)
Step 1: Turn off breaker. Step 2: Open condensing unit panel. Step 3: Photograph ALL wiring on the contactor. Step 4: Label each wire with tape. Step 5: Disconnect wires and remove old contactor. Step 6: Mount new contactor, reconnect wires matching your photo. Step 7: Restore power and test.
My AC clicks but the compressor won’t turn on. What’s wrong?
Clicking from the outdoor unit without the compressor starting = worn contactor. The contactor sends power to the compressor. When its contacts are pitted, it clicks but can’t make solid contact. Look for: visible pitting/burn marks on the contactor face, intermittent operation, or buzzing.
Is this contactor compatible with Bryant or Payne too?
Many Tempstar parts are cross-compatible with Bryant and Payne since all three brands are manufactured by Carrier Global Corporation. The same physical part is often used across brand labels with different model numbers. To verify: check your Bryant or Payne equipment service manual for cross-compatible part numbers, or email info@nationalhvacparts.com with your model number.
Should I use OEM or aftermarket for my Tempstar contactor?
OEM recommended for reliability and warranty compatibility. OEM parts match exact factory specifications for proper fit, performance, and safety. While aftermarket alternatives cost less upfront, the risk of improper fit and reduced lifespan usually makes OEM the better value long-term.
How fast does National HVAC Parts ship?
Orders placed before 3:00 PM CST ship the same business day. Standard delivery is 2–5 business days anywhere in the continental United States. Express shipping available at checkout. We ship from Houston, TX to all 50 states. 30-day return policy on all parts.
Home Shop Search Account Cart
Fitment Guaranteed
MR
Mike Rivera
HVAC Parts Specialist — Online