This genuine OEM contactor (part number 1172472) is a 1-pole, 30-amp unit with a 24V coil and an integrated shunt, used on the Tempstar TCA924GKA200 condensing unit. The contactor is the electrically operated switch that closes the high-voltage circuit to the compressor and condenser fan whenever the 24V control circuit calls for cooling. Contactors wear out from arcing, pitted or welded contacts, and failed coils. A bad contactor shows up as a unit that won't start, chatters, or a compressor that won't shut off because the contacts have welded closed. The shunt provides the proper bypass path for this model's wiring.

Specifications

Spec Value
Part Number 1172472
Type Definite purpose contactor, 1-pole, with shunt
Brand Tempstar
Rating 30A
Coil Voltage 24V
Poles 1
Fitment OEM replacement

Compatibility

Direct OEM fit for the Tempstar TCA924GKA200 condensing unit and related ICP/Heil/Comfortmaker condensers specifying a 1-pole 30A 24V-coil contactor with shunt. Confirm pole count, amp rating, 24V coil, and part number 1172472 against the original before wiring.

Installation Guide

  1. Safety First — Disconnect power at the breaker and disconnect, then verify zero voltage with a multimeter.
  2. Access — Remove the condenser service panel to reach the contactor.
  3. Document — Photograph all line, load, coil, and shunt connections before disconnecting.
  4. Remove — Transfer wires one at a time or label them, then unscrew the old contactor from its mounting base.
  5. Install — Mount the new contactor, reconnect line/load, 24V coil, and shunt leads exactly per your photo.
  6. Test — Restore power, call for cooling, and verify the contactor pulls in cleanly and energizes the compressor and fan.

Signs You Need a Replacement

  • Unit won't start or chatters when calling for cooling
  • Visible pitting, burning, or melted plastic on the contacts
  • Compressor won't shut off (contacts welded closed)
  • 24V coil reads open and the contactor won't pull in

Shipping & Returns

Ships same day on orders placed before 3 PM CST. 30-day hassle-free returns. Backed by the National HVAC Parts fitment guarantee.

Shipping Information

  • Orders placed before 3PM CST ship same business day
  • Standard delivery: 2-5 business days
  • Express shipping available at checkout
  • Free shipping on orders over $75
  • Tracking number emailed upon shipment

Return Policy

  • 30-day returns on unused parts in original packaging
  • Electrical parts (capacitors, contactors, control boards) are final sale once installed
  • Email info@nationalhvacparts.com to initiate a return
  • Refunds processed within 5-7 business days

Frequently Asked Questions

Does this Contactor fit my Tempstar TCA924GKA200 — 1-Pole 30A 24V Coil w/ Shunt | Ships Today?
Yes. This is the factory-specified OEM contactor for the Tempstar TCA924GKA200 — 1-Pole 30A 24V Coil w/ Shunt | Ships Today. It is a direct drop-in replacement that fits without modification. Always verify the model number on your equipment nameplate before ordering.
How do I replace the contactor on my Tempstar TCA924GKA200 — 1-Pole 30A 24V Coil w/ Shunt | Ships Today?
Difficulty: Medium (30–45 min)
Step 1: Turn off breaker. Step 2: Open condensing unit panel. Step 3: Photograph ALL wiring on the contactor. Step 4: Label each wire with tape. Step 5: Disconnect wires and remove old contactor. Step 6: Mount new contactor, reconnect wires matching your photo. Step 7: Restore power and test.
My AC clicks but the compressor won’t turn on. What’s wrong?
Clicking from the outdoor unit without the compressor starting = worn contactor. The contactor sends power to the compressor. When its contacts are pitted, it clicks but can’t make solid contact. Look for: visible pitting/burn marks on the contactor face, intermittent operation, or buzzing.
Is this contactor compatible with Bryant or Payne too?
Many Tempstar parts are cross-compatible with Bryant and Payne since all three brands are manufactured by Carrier Global Corporation. The same physical part is often used across brand labels with different model numbers. To verify: check your Bryant or Payne equipment service manual for cross-compatible part numbers, or email info@nationalhvacparts.com with your model number.
Should I use OEM or aftermarket for my Tempstar contactor?
OEM recommended for reliability and warranty compatibility. OEM parts match exact factory specifications for proper fit, performance, and safety. While aftermarket alternatives cost less upfront, the risk of improper fit and reduced lifespan usually makes OEM the better value long-term.
How fast does National HVAC Parts ship?
Orders placed before 3:00 PM CST ship the same business day. Standard delivery is 2–5 business days anywhere in the continental United States. Express shipping available at checkout. We ship from Houston, TX to all 50 states. 30-day return policy on all parts.
Home Shop Search Account Cart
Fitment Guaranteed
MR
Mike Rivera
HVAC Parts Specialist — Online