Overview

This genuine OEM single-pole definite purpose contactor (part number 1050699) is the correct replacement for the Tempstar TCA242VKA1 condensing unit. The contactor is the electrically operated switch that powers the compressor and condenser fan motor whenever the thermostat calls for cooling. Its 24-volt control coil closes a set of power contacts rated for 25 amps, completing the high-voltage circuit to the outdoor unit. A worn or failed contactor commonly causes an outdoor unit that won't start, a contactor that buzzes or chatters, pitted or welded contacts that keep the compressor running continuously, or arcing and burn marks at the terminals. Because the contactor cycles thousands of times each season, it is one of the most frequently replaced parts in a cooling system.

Specifications

Spec Value
Part Number 1050699
Type Definite Purpose Contactor, 1-Pole
Brand Tempstar (ICP / Heil family)
Contact Rating 25 Amps
Coil Voltage 24 VAC
Poles 1
Fitment OEM Replacement

Compatibility

A direct OEM replacement for the Tempstar TCA242VKA1 condensing unit. The 1050699 contactor is also used across many ICP-built outdoor units sold under the Tempstar, Heil, Comfortmaker, and Arcoaire brands. Confirm the existing part number (1050699) and 24V coil rating before ordering.

Installation Guide

  1. Safety First — Disconnect power at the outdoor disconnect and breaker, then verify zero voltage with a multimeter across the line terminals.
  2. Access — Remove the electrical access panel on the condensing unit.
  3. Document — Photograph every wire and terminal before disconnecting anything.
  4. Remove — Transfer the line, load, and 24V coil leads one at a time, then unscrew the old contactor from its bracket.
  5. Install — Mount the new 1050699 contactor and reconnect each wire to the matching terminal per your photo.
  6. Test — Restore power, call for cooling, and confirm the contactor pulls in cleanly and the compressor and fan start.

Signs You Need a Replacement

  • Outdoor unit will not start on a cooling call.
  • Buzzing, humming, or chattering from the contactor.
  • Pitted or welded contacts that keep the compressor running nonstop.
  • Arcing, melted plastic, or scorch marks on the terminals.

Shipping & Returns

Ships same day before 3 PM CST. 30-day returns. Backed by the National HVAC Parts fitment guarantee.

Shipping Information

  • Orders placed before 3PM CST ship same business day
  • Standard delivery: 2-5 business days
  • Express shipping available at checkout
  • Free shipping on orders over $75
  • Tracking number emailed upon shipment

Return Policy

  • 30-day returns on unused parts in original packaging
  • Electrical parts (capacitors, contactors, control boards) are final sale once installed
  • Email info@nationalhvacparts.com to initiate a return
  • Refunds processed within 5-7 business days

Frequently Asked Questions

Does this Contactor fit my Tempstar TCA242VKA1 — 1-Pole 25A 24V Coil | Ships Today?
Yes. This is the factory-specified OEM contactor for the Tempstar TCA242VKA1 — 1-Pole 25A 24V Coil | Ships Today. It is a direct drop-in replacement that fits without modification. Always verify the model number on your equipment nameplate before ordering.
How do I replace the contactor on my Tempstar TCA242VKA1 — 1-Pole 25A 24V Coil | Ships Today?
Difficulty: Medium (30–45 min)
Step 1: Turn off breaker. Step 2: Open condensing unit panel. Step 3: Photograph ALL wiring on the contactor. Step 4: Label each wire with tape. Step 5: Disconnect wires and remove old contactor. Step 6: Mount new contactor, reconnect wires matching your photo. Step 7: Restore power and test.
My AC clicks but the compressor won’t turn on. What’s wrong?
Clicking from the outdoor unit without the compressor starting = worn contactor. The contactor sends power to the compressor. When its contacts are pitted, it clicks but can’t make solid contact. Look for: visible pitting/burn marks on the contactor face, intermittent operation, or buzzing.
Is this contactor compatible with Bryant or Payne too?
Many Tempstar parts are cross-compatible with Bryant and Payne since all three brands are manufactured by Carrier Global Corporation. The same physical part is often used across brand labels with different model numbers. To verify: check your Bryant or Payne equipment service manual for cross-compatible part numbers, or email info@nationalhvacparts.com with your model number.
Should I use OEM or aftermarket for my Tempstar contactor?
OEM recommended for reliability and warranty compatibility. OEM parts match exact factory specifications for proper fit, performance, and safety. While aftermarket alternatives cost less upfront, the risk of improper fit and reduced lifespan usually makes OEM the better value long-term.
How fast does National HVAC Parts ship?
Orders placed before 3:00 PM CST ship the same business day. Standard delivery is 2–5 business days anywhere in the continental United States. Express shipping available at checkout. We ship from Houston, TX to all 50 states. 30-day return policy on all parts.