Same-day shipping before 3PM CST · 35,000+ OEM Parts · Texas CMBL & SAM.gov Registered · Government POs Accepted

Menu

Home Shop All Account Cart
Tempstar Contactor for T2A342GKD200 — 1-Pole 30A 24V w/Shunt | Ships Today
Tempstar

Tempstar Contactor for T2A342GKD200 — 1-Pole 30A 24V w/Shunt | Ships Today

SKU: 1172472-GEN Brand: Tempstar

OEM Guaranteed

Same-Day Ship

30-Day Returns

Secure Checkout

Texas CMBL #19328542014
SAM.gov Registered
Govt POs Accepted

Overview

This OEM 1-pole definite purpose contactor (part number 1172472) is the electrical switch that powers the compressor and condenser fan in the Tempstar T2A342GKD200 system. With a 30-amp contact rating, a 24V control coil, and an integrated shunt, it energizes on every thermostat cooling call to feed line voltage to the outdoor unit. The contact points endure constant arcing and mechanical wear, and over time they pit and burn until they fail to conduct reliably. Symptoms of a bad contactor include a condenser that hums but won't start, a unit that runs continuously, or an outdoor cabinet that is completely dead. A genuine OEM replacement restores dependable switching and protects the compressor from damaging low-voltage conditions.

Specifications

Spec Value
OEM Part Number 1172472
Type Definite Purpose Contactor
Poles 1 (Single Pole)
Contact Rating 30 Amps
Coil Voltage 24 VAC
Feature With Shunt
Brand Tempstar

Compatibility

Directly fits the Tempstar T2A342GKD200 condensing unit and other ICP/Tempstar-family equipment (Heil, Comfortmaker) using the 1172472 contactor. Verify poles, amp rating, and coil voltage against your existing part before ordering.

Installation Guide

  1. Safety First — Disconnect power at the outdoor disconnect and breaker, then confirm zero voltage at the terminals with a multimeter.
  2. Access — Remove the condenser service panel to expose the control compartment.
  3. Document — Photograph all line, load, and coil wiring before disconnecting.
  4. Remove — Move wires off the old contactor one at a time, then unscrew it from the bracket.
  5. Install — Mount the new contactor and reconnect each wire to the matching terminal per your photo.
  6. Test — Restore power, call for cooling, and verify the contacts pull in and the unit starts.

Signs You Need a Replacement

  • Condenser hums or buzzes but won't start.
  • Pitted, burned, or melted contact points.
  • Unit won't shut off after cooling is satisfied (welded contacts).
  • Chattering or rapid clicking on a cooling call.

Shipping & Returns

Ships same day before 3 PM CST. 30-day returns. Backed by the National HVAC Parts fitment guarantee.

Shipping Information

  • Orders placed before 3PM CST ship same business day
  • Standard delivery: 2-5 business days
  • Express shipping available at checkout
  • Free shipping on orders over $75
  • Tracking number emailed upon shipment

Return Policy

  • 30-day returns on unused parts in original packaging
  • Electrical parts (capacitors, contactors, control boards) are final sale once installed
  • Email info@nationalhvacparts.com to initiate a return
  • Refunds processed within 5-7 business days

Frequently Asked Questions

Does this Contactor fit my Tempstar T2A342GKD200 — 1-Pole 30A 24V w/Shunt | Ships Today?
Yes. This is the factory-specified OEM contactor for the Tempstar T2A342GKD200 — 1-Pole 30A 24V w/Shunt | Ships Today. It is a direct drop-in replacement that fits without modification. Always verify the model number on your equipment nameplate before ordering.
How do I replace the contactor on my Tempstar T2A342GKD200 — 1-Pole 30A 24V w/Shunt | Ships Today?
Difficulty: Medium (30–45 min)
Step 1: Turn off breaker. Step 2: Open condensing unit panel. Step 3: Photograph ALL wiring on the contactor. Step 4: Label each wire with tape. Step 5: Disconnect wires and remove old contactor. Step 6: Mount new contactor, reconnect wires matching your photo. Step 7: Restore power and test.
My AC clicks but the compressor won’t turn on. What’s wrong?
Clicking from the outdoor unit without the compressor starting = worn contactor. The contactor sends power to the compressor. When its contacts are pitted, it clicks but can’t make solid contact. Look for: visible pitting/burn marks on the contactor face, intermittent operation, or buzzing.
Is this contactor compatible with Bryant or Payne too?
Many Tempstar parts are cross-compatible with Bryant and Payne since all three brands are manufactured by Carrier Global Corporation. The same physical part is often used across brand labels with different model numbers. To verify: check your Bryant or Payne equipment service manual for cross-compatible part numbers, or email info@nationalhvacparts.com with your model number.
Should I use OEM or aftermarket for my Tempstar contactor?
OEM recommended for reliability and warranty compatibility. OEM parts match exact factory specifications for proper fit, performance, and safety. While aftermarket alternatives cost less upfront, the risk of improper fit and reduced lifespan usually makes OEM the better value long-term.
How fast does National HVAC Parts ship?
Orders placed before 3:00 PM CST ship the same business day. Standard delivery is 2–5 business days anywhere in the continental United States. Express shipping available at checkout. We ship from Houston, TX to all 50 states. 30-day return policy on all parts.
Home Shop Search Account Cart
Fitment Guaranteed
MR
Mike Rivera
HVAC Parts Specialist — Online