Same-day shipping before 3PM CST · 35,000+ OEM Parts · Texas CMBL & SAM.gov Registered · Government POs Accepted

Menu

Home Shop All Account Cart
Tempstar Condenser Fan Motor for TXA648GKA100 — 1/4 HP OEM | Ships Today
Tempstar

Tempstar Condenser Fan Motor for TXA648GKA100 — 1/4 HP OEM | Ships Today

SKU: 1177473-GEN Brand: Tempstar

OEM Guaranteed

Same-Day Ship

30-Day Returns

Secure Checkout

Texas CMBL #19328542014
SAM.gov Registered
Govt POs Accepted

Overview

This is the genuine OEM 1/4 HP condenser fan motor (part #1177473) for the Tempstar TXA648GKA100 outdoor unit. The condenser fan motor drives the fan that pulls air across the outdoor coil so the system can reject the heat it removes from the home. When this motor fails, the compressor loses adequate heat rejection, head pressure rises, and the unit overheats and trips its high-pressure or overload protection. Typical failure symptoms include a fan that hums but won't start, a fan that turns slowly, bearing noise or grinding, intermittent operation as the motor overheats, and a condenser that runs hot. Fitting the correct 1/4 HP OEM motor restores proper airflow and protects the compressor from heat-related damage.

Specifications

Spec Value
Part Number 1177473
Type Condenser Fan Motor
Brand Tempstar
Horsepower 1/4 HP
Application Condenser / Outdoor Fan
Fit OEM Direct Replacement

Compatibility

Engineered as a direct OEM replacement for the Tempstar TXA648GKA100 condensing unit. This is the factory-specified motor for that model and is shared across related ICP / Heil / Comfortmaker condensers built on the TXA chassis. Confirm against your unit's nameplate and the existing motor data plate before installing.

Installation Guide

  1. Safety First — Disconnect power at the outdoor disconnect and breaker, then verify zero voltage at the contactor with a multimeter.
  2. Access — Remove the top fan grille/panel screws and lift the fan assembly clear of the cabinet.
  3. Document — Photograph all motor wiring and run-capacitor connections before disconnecting.
  4. Remove — Loosen the fan blade set screw, pull the blade, then unbolt the old motor from the bracket and disconnect its leads.
  5. Install — Mount the new 1/4 HP motor, transfer the fan blade to the same depth, and reconnect leads to the capacitor and contactor per your photo.
  6. Test — Restore power, confirm the fan starts immediately and rotates in the correct direction (drawing air up), and verify normal head pressure.

Signs You Need a Replacement

  • Fan hums but does not spin, or needs a push to start
  • Outdoor unit overheats or trips on high-pressure / overload
  • Grinding, squealing, or rattling bearing noise from the fan motor
  • Fan runs slow or cycles on and off as the motor overheats

Shipping & Returns

Ships same day before 3 PM CST. 30-day returns. Backed by the National HVAC Parts fitment guarantee.

Shipping Information

  • Orders placed before 3PM CST ship same business day
  • Standard delivery: 2-5 business days
  • Express shipping available at checkout
  • Free shipping on orders over $75
  • Tracking number emailed upon shipment

Return Policy

  • 30-day returns on unused parts in original packaging
  • Electrical parts (capacitors, contactors, control boards) are final sale once installed
  • Email info@nationalhvacparts.com to initiate a return
  • Refunds processed within 5-7 business days

Frequently Asked Questions

Does this Fan Motor fit my Tempstar TXA648GKA100 — 1/4 HP OEM | Ships Today?
Yes. This is the factory-specified OEM fan motor for the Tempstar TXA648GKA100 — 1/4 HP OEM | Ships Today. It is a direct drop-in replacement that fits without modification. Always verify the model number on your equipment nameplate before ordering.
How do I replace the fan motor on my Tempstar TXA648GKA100 — 1/4 HP OEM | Ships Today?
Difficulty: Medium-Hard (1–2 hrs)
Step 1: Turn off breaker. Step 2: Note motor specs: HP, RPM, voltage, rotation direction. Step 3: Remove old motor from mounting. Step 4: Transfer fan blade to new motor. Step 5: Mount new motor, reconnect wiring. Step 6: Restore power, verify rotation direction.
My AC fan isn’t spinning. What part do I need?
Fan not spinning, spinning slowly, or making grinding/squealing noises = motor failure. Grinding = bearings failed. Squealing = bearings dry. No spin + hum = check the motor capacitor first before replacing the entire motor.
Is this fan motor compatible with Bryant or Payne too?
Many Tempstar parts are cross-compatible with Bryant and Payne since all three brands are manufactured by Carrier Global Corporation. The same physical part is often used across brand labels with different model numbers. To verify: check your Bryant or Payne equipment service manual for cross-compatible part numbers, or email info@nationalhvacparts.com with your model number.
Should I use OEM or aftermarket for my Tempstar fan motor?
OEM recommended for reliability and warranty compatibility. OEM parts match exact factory specifications for proper fit, performance, and safety. While aftermarket alternatives cost less upfront, the risk of improper fit and reduced lifespan usually makes OEM the better value long-term.
How fast does National HVAC Parts ship?
Orders placed before 3:00 PM CST ship the same business day. Standard delivery is 2–5 business days anywhere in the continental United States. Express shipping available at checkout. We ship from Houston, TX to all 50 states. 30-day return policy on all parts.