Same-day shipping before 3PM CST · 35,000+ OEM Parts · Texas CMBL & SAM.gov Registered · Government POs Accepted

Menu

Home Shop All Account Cart
Tempstar Condenser Fan Motor for T4H360GKD400 — 1/4 HP OEM | Ships Today
Tempstar

Tempstar Condenser Fan Motor for T4H360GKD400 — 1/4 HP OEM | Ships Today

SKU: 1177473-GEN Brand: Tempstar

OEM Guaranteed

Same-Day Ship

30-Day Returns

Secure Checkout

Texas CMBL #19328542014
SAM.gov Registered
Govt POs Accepted

Overview

This is a genuine OEM 1/4 HP condenser fan motor (part number 1177473) for the Tempstar T4H360GKD400 heat pump system. The condenser fan motor drives the outdoor fan blade that pulls air across the condenser coil, rejecting heat in cooling mode and absorbing it in heating mode. When this motor fails, the unit can no longer move air across the coil, causing high head pressure, overheating compressors, tripped breakers, and a complete loss of cooling or heating capacity. A failing motor often shows up as a hot, humming outdoor unit with a fan blade that will not spin or that spins only when pushed by hand.

Specifications

Spec Value
Part Number 1177473
Type Condenser Fan Motor
Brand Tempstar
Horsepower 1/4 HP
Application Outdoor condenser fan
Fit OEM direct replacement

Compatibility

Engineered as a direct-fit replacement for the Tempstar T4H360GKD400 heat pump. Because Tempstar, Heil, Comfortmaker, and other ICP brands share platforms, this 1/4 HP motor also services equivalent ICP-built condensing units using the same OEM part number. Always confirm the motor's HP, voltage, and rotation against your existing unit's data plate before installing.

Installation Guide

  1. Safety First — Disconnect power at the outdoor disconnect and verify zero voltage with a multimeter before touching any wiring.
  2. Access — Remove the top grille and fan shroud screws to lift the fan assembly clear of the cabinet.
  3. Document — Photograph all motor wire connections and the fan blade position on the shaft before disconnecting anything.
  4. Remove — Loosen the fan blade set screw, slide the blade off, then unbolt the old motor from the shroud and cut or disconnect its leads.
  5. Install — Mount the new motor to the shroud, reinstall the blade at the same shaft depth, and reconnect the wires exactly per your photo.
  6. Test — Restore power and confirm the fan spins freely in the correct direction and the unit reaches normal operating pressures.

Signs You Need a Replacement

  • Outdoor fan blade does not turn while the compressor runs
  • Motor hums but will not start, or only starts with a hand spin
  • Outdoor unit runs hot, trips on high pressure, or shuts down on overload
  • Bearings are noisy, grinding, or the shaft has play and wobble

Shipping & Returns

Ships same day for orders placed before 3 PM CST. 30-day returns on unused parts. Backed by the National HVAC Parts fitment guarantee.

Shipping Information

  • Orders placed before 3PM CST ship same business day
  • Standard delivery: 2-5 business days
  • Express shipping available at checkout
  • Free shipping on orders over $75
  • Tracking number emailed upon shipment

Return Policy

  • 30-day returns on unused parts in original packaging
  • Electrical parts (capacitors, contactors, control boards) are final sale once installed
  • Email info@nationalhvacparts.com to initiate a return
  • Refunds processed within 5-7 business days

Frequently Asked Questions

Does this Fan Motor fit my Tempstar T4H360GKD400 — 1/4 HP OEM | Ships Today?
Yes. This is the factory-specified OEM fan motor for the Tempstar T4H360GKD400 — 1/4 HP OEM | Ships Today. It is a direct drop-in replacement that fits without modification. Always verify the model number on your equipment nameplate before ordering.
How do I replace the fan motor on my Tempstar T4H360GKD400 — 1/4 HP OEM | Ships Today?
Difficulty: Medium-Hard (1–2 hrs)
Step 1: Turn off breaker. Step 2: Note motor specs: HP, RPM, voltage, rotation direction. Step 3: Remove old motor from mounting. Step 4: Transfer fan blade to new motor. Step 5: Mount new motor, reconnect wiring. Step 6: Restore power, verify rotation direction.
My AC fan isn’t spinning. What part do I need?
Fan not spinning, spinning slowly, or making grinding/squealing noises = motor failure. Grinding = bearings failed. Squealing = bearings dry. No spin + hum = check the motor capacitor first before replacing the entire motor.
Is this fan motor compatible with Bryant or Payne too?
Many Tempstar parts are cross-compatible with Bryant and Payne since all three brands are manufactured by Carrier Global Corporation. The same physical part is often used across brand labels with different model numbers. To verify: check your Bryant or Payne equipment service manual for cross-compatible part numbers, or email info@nationalhvacparts.com with your model number.
Should I use OEM or aftermarket for my Tempstar fan motor?
OEM recommended for reliability and warranty compatibility. OEM parts match exact factory specifications for proper fit, performance, and safety. While aftermarket alternatives cost less upfront, the risk of improper fit and reduced lifespan usually makes OEM the better value long-term.
How fast does National HVAC Parts ship?
Orders placed before 3:00 PM CST ship the same business day. Standard delivery is 2–5 business days anywhere in the continental United States. Express shipping available at checkout. We ship from Houston, TX to all 50 states. 30-day return policy on all parts.
Home Shop Search Account Cart
Fitment Guaranteed
MR
Mike Rivera
HVAC Parts Specialist — Online