Same-day shipping before 3PM CST · 35,000+ OEM Parts · Texas CMBL & SAM.gov Registered · Government POs Accepted

Menu

Home Shop All Account Cart
Tempstar Condenser Fan Motor for T4A436GKD100 — 1/5 HP | Ships Today
Tempstar

Tempstar Condenser Fan Motor for T4A436GKD100 — 1/5 HP | Ships Today

SKU: 1177593-GEN Brand: Tempstar

OEM Guaranteed

Same-Day Ship

30-Day Returns

Secure Checkout

Texas CMBL #19328542014
SAM.gov Registered
Govt POs Accepted

Overview

This is a genuine OEM 1/5 HP condenser fan motor (part number 1177593) for the Tempstar T4A436GKD100 air conditioning condenser. The condenser fan motor spins the outdoor fan blade that pulls air across the condenser coil, rejecting heat from the refrigerant so the system can cool your home. When this motor fails, the compressor continues to run but cannot shed heat, leading to high head pressure, short cycling on the high-pressure or thermal limit, warm air at the registers, and eventual compressor damage. Common failure symptoms include a humming outdoor unit with a stationary or slow-turning fan, a fan that needs a push to start, a burnt-electrical smell, or a unit that trips its breaker. Replacing the motor promptly protects the far more expensive compressor.

Specifications

Spec Value
Part Number 1177593
Type Condenser Fan Motor
Brand Tempstar (ICP / Heil family)
Horsepower 1/5 HP
Fitment OEM direct replacement
Application Outdoor condenser fan

Compatibility

Engineered as a direct OEM fit for the Tempstar T4A436GKD100 condensing unit. This motor is shared across the ICP / Heil / Tempstar / Comfortmaker family of equipment that uses part 1177593. Always confirm the part number on your existing motor label before ordering.

Installation Guide

  1. Safety First — Disconnect power at the outdoor disconnect and verify zero voltage with a multimeter at the motor leads.
  2. Access — Remove the top grille/fan shroud screws and lift the fan assembly clear of the cabinet.
  3. Document — Photograph all wire connections and the fan blade position/spacing before disconnecting anything.
  4. Remove — Loosen the fan blade set screw, pull the blade, then unbolt the old motor from the shroud and disconnect the leads.
  5. Install — Mount the new motor with the shaft facing the same direction, reinstall the blade at the recorded height, and reconnect leads per your photo and the new motor's wiring diagram.
  6. Test — Restore power, confirm the fan spins freely in the correct direction, and verify the unit cools with normal operating pressures.

Signs You Need a Replacement

  • Outdoor unit hums but the fan does not spin, or needs a manual push to start.
  • Warm air at the supply registers while the condenser is running.
  • Hot, noisy, or grinding motor bearings, or a burnt-electrical odor.
  • Repeated high-pressure trips or breaker trips during a cooling call.

Shipping & Returns

Ships same day before 3 PM CST. 30-day returns. Backed by the National HVAC Parts fitment guarantee.

Shipping Information

  • Orders placed before 3PM CST ship same business day
  • Standard delivery: 2-5 business days
  • Express shipping available at checkout
  • Free shipping on orders over $75
  • Tracking number emailed upon shipment

Return Policy

  • 30-day returns on unused parts in original packaging
  • Electrical parts (capacitors, contactors, control boards) are final sale once installed
  • Email info@nationalhvacparts.com to initiate a return
  • Refunds processed within 5-7 business days

Frequently Asked Questions

Does this Fan Motor fit my Tempstar T4A436GKD100 — 1/5 HP | Ships Today?
Yes. This is the factory-specified OEM fan motor for the Tempstar T4A436GKD100 — 1/5 HP | Ships Today. It is a direct drop-in replacement that fits without modification. Always verify the model number on your equipment nameplate before ordering.
How do I replace the fan motor on my Tempstar T4A436GKD100 — 1/5 HP | Ships Today?
Difficulty: Medium-Hard (1–2 hrs)
Step 1: Turn off breaker. Step 2: Note motor specs: HP, RPM, voltage, rotation direction. Step 3: Remove old motor from mounting. Step 4: Transfer fan blade to new motor. Step 5: Mount new motor, reconnect wiring. Step 6: Restore power, verify rotation direction.
My AC fan isn’t spinning. What part do I need?
Fan not spinning, spinning slowly, or making grinding/squealing noises = motor failure. Grinding = bearings failed. Squealing = bearings dry. No spin + hum = check the motor capacitor first before replacing the entire motor.
Is this fan motor compatible with Bryant or Payne too?
Many Tempstar parts are cross-compatible with Bryant and Payne since all three brands are manufactured by Carrier Global Corporation. The same physical part is often used across brand labels with different model numbers. To verify: check your Bryant or Payne equipment service manual for cross-compatible part numbers, or email info@nationalhvacparts.com with your model number.
Should I use OEM or aftermarket for my Tempstar fan motor?
OEM recommended for reliability and warranty compatibility. OEM parts match exact factory specifications for proper fit, performance, and safety. While aftermarket alternatives cost less upfront, the risk of improper fit and reduced lifespan usually makes OEM the better value long-term.
How fast does National HVAC Parts ship?
Orders placed before 3:00 PM CST ship the same business day. Standard delivery is 2–5 business days anywhere in the continental United States. Express shipping available at checkout. We ship from Houston, TX to all 50 states. 30-day return policy on all parts.
Home Shop Search Account Cart
Fitment Guaranteed
MR
Mike Rivera
HVAC Parts Specialist — Online