Tempstar Condenser Fan Motor for T2H360GKD100 — 1/4 HP | Ships Today
Tempstar

Tempstar Condenser Fan Motor for T2H360GKD100 — 1/4 HP | Ships Today

SKU: 1177473-GEN Brand: Tempstar

OEM Guaranteed

Same-Day Ship

30-Day Returns

Secure Checkout

Texas CMBL #19328542014
SAM.gov Registered
Govt POs Accepted

Overview

This is the genuine OEM 1/4 HP condenser fan motor (part number 1177473) for the Tempstar T2H360GKD100 heat pump. The condenser fan motor spins the outdoor blade that pulls air across the condenser coil, rejecting heat in cooling mode and absorbing heat in heating mode. A failing motor causes head pressure to spike, the compressor to overheat and trip on overload, and cooling or heating output to fall off. Typical failure signs are a fan that hums but won't spin, screeching or grinding bearings, a motor running hot enough to trip its internal overload, or a unit short-cycling on high-pressure faults. Replacing the motor early protects the much costlier compressor it shares power with.

Specifications

Spec Value
Part Number 1177473
Type Condenser Fan Motor
Brand Tempstar (ICP / Heil)
Horsepower 1/4 HP
Application Outdoor condenser fan
Fit OEM direct replacement

Compatibility

Direct-fit replacement for the Tempstar T2H360GKD100 and equivalent ICP, Heil, and Comfortmaker heat pumps built on the same outdoor section. Verify horsepower, rotation, voltage, and shaft diameter against the old motor before installing.

Installation Guide

  1. Safety First — Disconnect power at the outdoor disconnect and verify zero voltage with a multimeter at the contactor.
  2. Access — Remove the top grille/fan shroud screws and lift the fan assembly out of the cabinet.
  3. Document — Photograph all motor and capacitor wires and the blade depth on the shaft before disconnecting.
  4. Remove — Loosen the blade set screw, pull the blade, then unbolt the old motor and free its leads.
  5. Install — Bolt the new motor to the shroud, reinstall the blade at the same depth, and reconnect leads and the run capacitor per your photos.
  6. Test — Restore power, confirm correct rotation and a smooth start, and verify full fan speed with no vibration.

Signs You Need a Replacement

  • Fan hums or buzzes but the blade won't turn.
  • Loud bearing screech, grinding, or wobble.
  • Outdoor unit trips on high-pressure or thermal overload.
  • Motor body runs too hot to touch or smells burnt.

Shipping & Returns

Ships same day before 3 PM CST. 30-day returns. Backed by the National HVAC Parts fitment guarantee.

Shipping Information

  • Orders placed before 3PM CST ship same business day
  • Standard delivery: 2-5 business days
  • Express shipping available at checkout
  • Free shipping on orders over $75
  • Tracking number emailed upon shipment

Return Policy

  • 30-day returns on unused parts in original packaging
  • Electrical parts (capacitors, contactors, control boards) are final sale once installed
  • Email info@nationalhvacparts.com to initiate a return
  • Refunds processed within 5-7 business days

Frequently Asked Questions

Does this Fan Motor fit my Tempstar T2H360GKD100 — 1/4 HP | Ships Today?
Yes. This is the factory-specified OEM fan motor for the Tempstar T2H360GKD100 — 1/4 HP | Ships Today. It is a direct drop-in replacement that fits without modification. Always verify the model number on your equipment nameplate before ordering.
How do I replace the fan motor on my Tempstar T2H360GKD100 — 1/4 HP | Ships Today?
Difficulty: Medium-Hard (1–2 hrs)
Step 1: Turn off breaker. Step 2: Note motor specs: HP, RPM, voltage, rotation direction. Step 3: Remove old motor from mounting. Step 4: Transfer fan blade to new motor. Step 5: Mount new motor, reconnect wiring. Step 6: Restore power, verify rotation direction.
My AC fan isn’t spinning. What part do I need?
Fan not spinning, spinning slowly, or making grinding/squealing noises = motor failure. Grinding = bearings failed. Squealing = bearings dry. No spin + hum = check the motor capacitor first before replacing the entire motor.
Is this fan motor compatible with Bryant or Payne too?
Many Tempstar parts are cross-compatible with Bryant and Payne since all three brands are manufactured by Carrier Global Corporation. The same physical part is often used across brand labels with different model numbers. To verify: check your Bryant or Payne equipment service manual for cross-compatible part numbers, or email info@nationalhvacparts.com with your model number.
Should I use OEM or aftermarket for my Tempstar fan motor?
OEM recommended for reliability and warranty compatibility. OEM parts match exact factory specifications for proper fit, performance, and safety. While aftermarket alternatives cost less upfront, the risk of improper fit and reduced lifespan usually makes OEM the better value long-term.
How fast does National HVAC Parts ship?
Orders placed before 3:00 PM CST ship the same business day. Standard delivery is 2–5 business days anywhere in the continental United States. Express shipping available at checkout. We ship from Houston, TX to all 50 states. 30-day return policy on all parts.
Home Shop Search Account Cart
Fitment Guaranteed
MR
Mike Rivera
HVAC Parts Specialist — Online