Same-day shipping before 3PM CST · 35,000+ OEM Parts · Texas CMBL & SAM.gov Registered · Government POs Accepted

Menu

Home Shop All Account Cart
Tempstar 40VA Transformer 208/230V to 24V for TCH924GKA200 — OEM 1170676 | Ships Today
Tempstar

Tempstar 40VA Transformer 208/230V to 24V for TCH924GKA200 — OEM 1170676 | Ships Today

SKU: 1172574-GEN Brand: Tempstar

OEM Guaranteed

Same-Day Ship

30-Day Returns

Secure Checkout

Texas CMBL #19328542014
SAM.gov Registered
Govt POs Accepted

Overview

This Tempstar 40VA control transformer (OEM part 1170676) steps the unit's 208/230V line voltage down to the 24V needed to power the thermostat, contactor coil, reversing-valve solenoid, and safety circuits. Rated at 40 volt-amps, it supplies adequate inrush current for the control loads on this heat pump chassis. A failed transformer produces a completely dead control circuit — no thermostat display, no contactor pull-in, and no call for cooling or heating. Failures are usually caused by a shorted low-voltage wire, a stuck contactor coil, or age-related winding breakdown.

Specifications

Spec Value
Part Number 1170676
Type Step-Down Control Transformer
Rating 40 VA
Primary 208/230V
Secondary 24V
Brand Tempstar / ICP / Heil

Compatibility

Direct OEM replacement for Tempstar model TCH924GKA200 and related ICP/Heil/Comfortmaker heat pump units. This listing also relates to companion control parts on the same model, including reversing valve coil (1172574) and reversing valve with coil assembly (1175621); order those separately if needed. Verify your VA rating and voltage taps before installing.

Installation Guide

  1. Safety First — Disconnect power and verify zero voltage with a multimeter.
  2. Access — Remove the unit service panel.
  3. Document — Photograph the primary and secondary wiring before disconnecting.
  4. Remove — Confirm the correct primary tap for your supply voltage, disconnect all leads, and unbolt the transformer from the control bracket.
  5. Install — Mount the new transformer, land the primary on the matching voltage tap, and reconnect the 24V secondary per your photo.
  6. Test — Restore power and confirm 24V at the secondary and proper contactor/thermostat operation.

Signs You Need a Replacement

  • Dead thermostat and no low-voltage anywhere in the system
  • No 24V reading across the secondary terminals
  • Burnt smell or visibly charred transformer windings
  • Repeated transformer failure pointing to a shorted control wire

Shipping & Returns

Ships same day before 3 PM CST. 30-day returns. Backed by the National HVAC Parts fitment guarantee.

Shipping Information

  • Orders placed before 3PM CST ship same business day
  • Standard delivery: 2-5 business days
  • Express shipping available at checkout
  • Free shipping on orders over $75
  • Tracking number emailed upon shipment

Return Policy

  • 30-day returns on unused parts in original packaging
  • Electrical parts (capacitors, contactors, control boards) are final sale once installed
  • Email info@nationalhvacparts.com to initiate a return
  • Refunds processed within 5-7 business days

Frequently Asked Questions

Does this Transformer fit my Tempstar TCH924GKA200 — OEM 1170676 | Ships Today?
Yes. This is the factory-specified OEM transformer for the Tempstar TCH924GKA200 — OEM 1170676 | Ships Today. It is a direct drop-in replacement that fits without modification. Always verify the model number on your equipment nameplate before ordering.
How do I replace the transformer on my Tempstar TCH924GKA200 — OEM 1170676 | Ships Today?
Difficulty: Medium (30–45 min)
Step 1: Turn off breaker. Step 2: Photo wiring connections. Step 3: Disconnect wires from old transformer. Step 4: Remove mounting hardware. Step 5: Install new transformer, reconnect wires matching voltage ratings. Step 6: Verify 24V output with multimeter.
My thermostat has no power. What failed?
Thermostat with no display = failed 24V transformer (or blown control board fuse). Check the 3A/5A fuse on the control board first ($1–$5 fix). If fuse is good but no 24V output from transformer, replace transformer.
Is this transformer compatible with Bryant or Payne too?
Many Tempstar parts are cross-compatible with Bryant and Payne since all three brands are manufactured by Carrier Global Corporation. The same physical part is often used across brand labels with different model numbers. To verify: check your Bryant or Payne equipment service manual for cross-compatible part numbers, or email info@nationalhvacparts.com with your model number.
Should I use OEM or aftermarket for my Tempstar transformer?
OEM recommended for reliability and warranty compatibility. OEM parts match exact factory specifications for proper fit, performance, and safety. While aftermarket alternatives cost less upfront, the risk of improper fit and reduced lifespan usually makes OEM the better value long-term.
How fast does National HVAC Parts ship?
Orders placed before 3:00 PM CST ship the same business day. Standard delivery is 2–5 business days anywhere in the continental United States. Express shipping available at checkout. We ship from Houston, TX to all 50 states. 30-day return policy on all parts.