This OEM 2-pole definite purpose contactor (part #1059574) is the main switching relay for the Tempstar TCH260AKC2 condensing unit. Rated at 40 amps with a 24-volt control coil, it sends line voltage to the compressor and condenser fan motor each time the thermostat calls for cooling. The high-current arcing that occurs every cycle gradually pits and burns the contacts, while the coil itself can open from age and heat. Typical failure signs are an outdoor unit that hums but won't start, audible chatter, or a system that never shuts off because the contacts have welded together.
| Spec | Value |
|---|---|
| Part Number | 1059574 |
| Type | 2-Pole Definite Purpose Contactor |
| Brand | Tempstar (ICP / Heil) |
| Amp Rating | 40A |
| Coil Voltage | 24V |
| Poles | 2 |
Direct OEM replacement for the Tempstar TCH260AKC2 heat pump/condenser. The TCH260 chassis is shared across the ICP family, so this contactor also services equivalent Heil, Comfortmaker, and Keeprite units. Confirm amp rating and coil voltage against the old part before installing.