Tempstar 2-Pole 40A 24V Contactor for TXA260AKA2 — OEM 1059574 | Ships Today
Tempstar

Tempstar 2-Pole 40A 24V Contactor for TXA260AKA2 — OEM 1059574 | Ships Today

SKU: 1059574-GEN Brand: Tempstar

OEM Guaranteed

Same-Day Ship

30-Day Returns

Secure Checkout

Texas CMBL #19328542014
SAM.gov Registered
Govt POs Accepted

Overview

This is the genuine OEM definite-purpose contactor (part number 1059574) for the Tempstar TXA260AKA2 condensing unit. It is a 2-pole, 40-amp contactor with a 24-volt control coil. The contactor is the electrically operated switch that energizes the compressor and condenser fan motor whenever the thermostat calls for cooling. When the 24V coil pulls in, both pole contacts close and pass line voltage to the load. Contactor failure is one of the most common no-cooling service calls: pitted, welded, or chattering contacts prevent the outdoor unit from starting or cause it to cycle erratically.

Specifications

Spec Value
Part Number 1059574
Type Definite Purpose Contactor
Brand Tempstar (ICP / Heil)
Poles 2-Pole
Contact Rating 40 Amps
Coil Voltage 24 VAC
Fits Model TXA260AKA2
Fitment OEM Genuine

Compatibility

Built for the Tempstar TXA260AKA2 air conditioner / heat pump condenser. This 2-pole 40A 24V contactor is used across the ICP family (Tempstar, Heil, Comfortmaker, Arcoaire) on condensing units of similar tonnage. Confirm the existing contactor reads 2-pole, 40A, and a 24V coil before ordering.

Installation Guide

  1. Safety First — Disconnect power at the outdoor disconnect and verify zero voltage with a multimeter at the line terminals.
  2. Access — Remove the condenser service panel to reach the contactor in the control box.
  3. Document — Photograph every line, load, and 24V coil wire before disconnecting.
  4. Remove — Transfer one wire at a time or label them, then unbolt the old contactor from its base.
  5. Install — Mount the new 1059574 contactor, reconnect each wire to the matching terminal per your photo.
  6. Test — Restore power, call for cooling, and confirm the coil pulls in and the compressor and fan start.

Signs You Need a Replacement

  • Outdoor unit won't start even though the thermostat calls for cooling
  • Loud buzzing, humming, or chattering from the contactor
  • Visibly burned, pitted, or welded contacts
  • Compressor runs continuously because contacts are stuck closed

Shipping & Returns

Ships same day before 3 PM CST. 30-day returns. Backed by the National HVAC Parts fitment guarantee.

Shipping Information

  • Orders placed before 3PM CST ship same business day
  • Standard delivery: 2-5 business days
  • Express shipping available at checkout
  • Free shipping on orders over $75
  • Tracking number emailed upon shipment

Return Policy

  • 30-day returns on unused parts in original packaging
  • Electrical parts (capacitors, contactors, control boards) are final sale once installed
  • Email info@nationalhvacparts.com to initiate a return
  • Refunds processed within 5-7 business days

Frequently Asked Questions

Does this Contactor fit my Tempstar TXA260AKA2 — OEM 1059574 | Ships Today?
Yes. This is the factory-specified OEM contactor for the Tempstar TXA260AKA2 — OEM 1059574 | Ships Today. It is a direct drop-in replacement that fits without modification. Always verify the model number on your equipment nameplate before ordering.
How do I replace the contactor on my Tempstar TXA260AKA2 — OEM 1059574 | Ships Today?
Difficulty: Medium (30–45 min)
Step 1: Turn off breaker. Step 2: Open condensing unit panel. Step 3: Photograph ALL wiring on the contactor. Step 4: Label each wire with tape. Step 5: Disconnect wires and remove old contactor. Step 6: Mount new contactor, reconnect wires matching your photo. Step 7: Restore power and test.
My AC clicks but the compressor won’t turn on. What’s wrong?
Clicking from the outdoor unit without the compressor starting = worn contactor. The contactor sends power to the compressor. When its contacts are pitted, it clicks but can’t make solid contact. Look for: visible pitting/burn marks on the contactor face, intermittent operation, or buzzing.
Is this contactor compatible with Bryant or Payne too?
Many Tempstar parts are cross-compatible with Bryant and Payne since all three brands are manufactured by Carrier Global Corporation. The same physical part is often used across brand labels with different model numbers. To verify: check your Bryant or Payne equipment service manual for cross-compatible part numbers, or email info@nationalhvacparts.com with your model number.
Should I use OEM or aftermarket for my Tempstar contactor?
OEM recommended for reliability and warranty compatibility. OEM parts match exact factory specifications for proper fit, performance, and safety. While aftermarket alternatives cost less upfront, the risk of improper fit and reduced lifespan usually makes OEM the better value long-term.
How fast does National HVAC Parts ship?
Orders placed before 3:00 PM CST ship the same business day. Standard delivery is 2–5 business days anywhere in the continental United States. Express shipping available at checkout. We ship from Houston, TX to all 50 states. 30-day return policy on all parts.