Same-day shipping before 3PM CST · 35,000+ OEM Parts · Texas CMBL & SAM.gov Registered · Government POs Accepted

Menu

Home Shop All Account Cart
Tempstar 1-Pole Contactor for TCH924GKA100 — 30A 24V Coil | Ships Today
Tempstar

Tempstar 1-Pole Contactor for TCH924GKA100 — 30A 24V Coil | Ships Today

SKU: 1172472-GEN Brand: Tempstar

OEM Guaranteed

Same-Day Ship

30-Day Returns

Secure Checkout

Texas CMBL #19328542014
SAM.gov Registered
Govt POs Accepted

Overview

This genuine OEM single-pole contactor (part number 1172472) switches line power to the compressor and outdoor fan on the Tempstar TCH924GKA100 heat pump. Rated at 30 amps with a 24V coil and an integrated shunt, the contactor is the heavy-duty relay the thermostat energizes every time the system calls for cooling or heating. When the thermostat sends 24V to the coil, the contactor's contacts pull in and feed full line voltage to the unit. Over thousands of cycles the contacts pit, burn, or weld, and the coil can fail open — leaving you with a humming, chattering, or completely dead outdoor unit. Replacing a worn contactor is a fast, inexpensive repair that prevents compressor damage from low or chattering voltage.

Specifications

Spec Value
Part Number 1172472
Type 1-Pole Definite Purpose Contactor
Brand Tempstar (ICP / Heil)
Contact Rating 30 Amps
Coil Voltage 24 VAC
Poles 1 (with shunt)
Fits Model TCH924GKA100

Compatibility

Engineered as the factory replacement for the Tempstar TCH924GKA100 heat pump. This 1-pole, 30A, 24V-coil contactor is a common service part across ICP-family units sold under the Heil, Comfortmaker, and Tempstar brands. Verify pole count, amp rating, and 24V coil before installing.

Installation Guide

  1. Safety First — Disconnect power at the disconnect and breaker. Verify zero voltage with a multimeter at the contactor line terminals.
  2. Access — Remove the condenser service panel to expose the contactor.
  3. Document — Photograph every line, load, and 24V coil wire before disconnecting.
  4. Remove — Transfer wires one at a time, or unclip the old contactor after labeling, then unscrew it from the bracket.
  5. Install — Mount the new contactor and reconnect each wire exactly as photographed.
  6. Test — Restore power, call for cooling, and confirm the contactor pulls in cleanly with no chatter.

Signs You Need a Replacement

  • Outdoor unit hums or chatters but the compressor won't start.
  • Pitted, burned, or welded contacts visible on inspection.
  • Buzzing coil or a contactor that won't pull in on a 24V call.
  • Intermittent cooling that improves when you tap the contactor.

Shipping & Returns

Ships same day on orders placed before 3 PM CST. 30-day hassle-free returns. Backed by the National HVAC Parts fitment guarantee.

Shipping Information

  • Orders placed before 3PM CST ship same business day
  • Standard delivery: 2-5 business days
  • Express shipping available at checkout
  • Free shipping on orders over $75
  • Tracking number emailed upon shipment

Return Policy

  • 30-day returns on unused parts in original packaging
  • Electrical parts (capacitors, contactors, control boards) are final sale once installed
  • Email info@nationalhvacparts.com to initiate a return
  • Refunds processed within 5-7 business days

Frequently Asked Questions

Does this Contactor fit my Tempstar TCH924GKA100 — 30A 24V Coil | Ships Today?
Yes. This is the factory-specified OEM contactor for the Tempstar TCH924GKA100 — 30A 24V Coil | Ships Today. It is a direct drop-in replacement that fits without modification. Always verify the model number on your equipment nameplate before ordering.
How do I replace the contactor on my Tempstar TCH924GKA100 — 30A 24V Coil | Ships Today?
Difficulty: Medium (30–45 min)
Step 1: Turn off breaker. Step 2: Open condensing unit panel. Step 3: Photograph ALL wiring on the contactor. Step 4: Label each wire with tape. Step 5: Disconnect wires and remove old contactor. Step 6: Mount new contactor, reconnect wires matching your photo. Step 7: Restore power and test.
My AC clicks but the compressor won’t turn on. What’s wrong?
Clicking from the outdoor unit without the compressor starting = worn contactor. The contactor sends power to the compressor. When its contacts are pitted, it clicks but can’t make solid contact. Look for: visible pitting/burn marks on the contactor face, intermittent operation, or buzzing.
Is this contactor compatible with Bryant or Payne too?
Many Tempstar parts are cross-compatible with Bryant and Payne since all three brands are manufactured by Carrier Global Corporation. The same physical part is often used across brand labels with different model numbers. To verify: check your Bryant or Payne equipment service manual for cross-compatible part numbers, or email info@nationalhvacparts.com with your model number.
Should I use OEM or aftermarket for my Tempstar contactor?
OEM recommended for reliability and warranty compatibility. OEM parts match exact factory specifications for proper fit, performance, and safety. While aftermarket alternatives cost less upfront, the risk of improper fit and reduced lifespan usually makes OEM the better value long-term.
How fast does National HVAC Parts ship?
Orders placed before 3:00 PM CST ship the same business day. Standard delivery is 2–5 business days anywhere in the continental United States. Express shipping available at checkout. We ship from Houston, TX to all 50 states. 30-day return policy on all parts.
Home Shop Search Account Cart
Fitment Guaranteed