Overview

This OEM single-pole contactor (Tempstar part 1050839) is the electrical switch that energizes the compressor and condenser fan in your Tempstar TCH042AKD1 system. Rated at 35 amps with a 24-volt control coil, it closes when the thermostat calls for cooling, sending line voltage to the compressor. Contactors are high-wear parts: their contacts pit and arc over thousands of cycles. A failed contactor causes the outdoor unit to stay silent, hum without starting, or — when contacts weld shut — run continuously even after the thermostat is satisfied.

Specifications

Spec Value
Part Number 1050839
Type Definite Purpose Contactor, 1-Pole
Brand Tempstar (ICP)
Contact Rating 35 Amps
Coil Voltage 24 VAC
Poles 1
Fitment OEM Replacement

Compatibility

Direct-fit OEM replacement for the Tempstar TCH042AKD1. This 35A 24V single-pole contactor is shared across many ICP-family condensing units (Tempstar, Heil, Comfortmaker) — confirm part 1050839 and the 24V coil rating before installing.

Installation Guide

  1. Safety First — Disconnect power at the outdoor disconnect and verify zero voltage with a multimeter.
  2. Access — Remove the condenser electrical-panel service cover.
  3. Document — Photograph every wire and terminal before disconnecting.
  4. Remove — Transfer wires one at a time, or label them, then unscrew and lift out the old contactor.
  5. Install — Mount the new contactor and reconnect line, load, and 24V coil leads exactly per your photo.
  6. Test — Restore power, call for cooling, and confirm the contactor pulls in and the compressor starts.

Signs You Need a Replacement

  • Outdoor unit hums but won't start
  • Pitted, blackened, or chattering contacts
  • Compressor runs nonstop (welded contacts)
  • Buzzing coil or no 24V pull-in

Shipping & Returns

Ships same day before 3 PM CST. 30-day returns. Backed by the National HVAC Parts fitment guarantee.

Shipping Information

  • Orders placed before 3PM CST ship same business day
  • Standard delivery: 2-5 business days
  • Express shipping available at checkout
  • Free shipping on orders over $75
  • Tracking number emailed upon shipment

Return Policy

  • 30-day returns on unused parts in original packaging
  • Electrical parts (capacitors, contactors, control boards) are final sale once installed
  • Email info@nationalhvacparts.com to initiate a return
  • Refunds processed within 5-7 business days

Frequently Asked Questions

Does this Contactor fit my Tempstar TCH042AKD1 — 24V Coil | Ships Today?
Yes. This is the factory-specified OEM contactor for the Tempstar TCH042AKD1 — 24V Coil | Ships Today. It is a direct drop-in replacement that fits without modification. Always verify the model number on your equipment nameplate before ordering.
How do I replace the contactor on my Tempstar TCH042AKD1 — 24V Coil | Ships Today?
Difficulty: Medium (30–45 min)
Step 1: Turn off breaker. Step 2: Open condensing unit panel. Step 3: Photograph ALL wiring on the contactor. Step 4: Label each wire with tape. Step 5: Disconnect wires and remove old contactor. Step 6: Mount new contactor, reconnect wires matching your photo. Step 7: Restore power and test.
My AC clicks but the compressor won’t turn on. What’s wrong?
Clicking from the outdoor unit without the compressor starting = worn contactor. The contactor sends power to the compressor. When its contacts are pitted, it clicks but can’t make solid contact. Look for: visible pitting/burn marks on the contactor face, intermittent operation, or buzzing.
Is this contactor compatible with Bryant or Payne too?
Many Tempstar parts are cross-compatible with Bryant and Payne since all three brands are manufactured by Carrier Global Corporation. The same physical part is often used across brand labels with different model numbers. To verify: check your Bryant or Payne equipment service manual for cross-compatible part numbers, or email info@nationalhvacparts.com with your model number.
Should I use OEM or aftermarket for my Tempstar contactor?
OEM recommended for reliability and warranty compatibility. OEM parts match exact factory specifications for proper fit, performance, and safety. While aftermarket alternatives cost less upfront, the risk of improper fit and reduced lifespan usually makes OEM the better value long-term.
How fast does National HVAC Parts ship?
Orders placed before 3:00 PM CST ship the same business day. Standard delivery is 2–5 business days anywhere in the continental United States. Express shipping available at checkout. We ship from Houston, TX to all 50 states. 30-day return policy on all parts.