This OEM single-pole, 30-amp definite-purpose contactor with integrated shunt (part 1172472) is the switching relay for the Tempstar T4H419GKD100 condensing unit. Its 24V coil energizes from the thermostat call, pulling the contacts closed to deliver line voltage to the compressor and condenser fan motor. A 1-pole contactor switches one leg of power while the other remains continuous. Contactors are a common wear item — the contacts pit and burn from repeated arcing, and the coil can fail open, leaving the outdoor unit dead on a cooling call.

Specifications

Spec Value
Part Number 1172472
Type Definite-Purpose Contactor
Brand Tempstar (ICP)
Poles 1-Pole (with shunt)
Contact Rating 30 Amps
Coil Voltage 24V

Compatibility

Designed for the Tempstar T4H419GKD100 and matching ICP/Heil/Comfortmaker condensing units that use a 1-pole 30A contactor with a 24V coil. Verify pole count, amp rating, and coil voltage against your existing part.

Installation Guide

  1. Safety First — Disconnect power and verify zero voltage with a multimeter.
  2. Access — Remove the condenser service/electrical panel.
  3. Document — Photograph all line, load, and 24V coil wiring before disconnecting.
  4. Remove — Note wire positions, disconnect each terminal, and unscrew the old contactor from its mount.
  5. Install — Mount the new contactor and reconnect each wire exactly per your photo.
  6. Test — Restore power, initiate a cooling call, and confirm the contactor pulls in and the compressor/fan start.

Signs You Need a Replacement

  • Outdoor unit won't start on a cooling call
  • Buzzing or chattering contactor
  • Pitted, burned, or welded contacts
  • Coil reads open on an ohm test

Shipping & Returns

Ships same day before 3 PM CST. 30-day returns. Backed by the National HVAC Parts fitment guarantee.

Shipping Information

  • Orders placed before 3PM CST ship same business day
  • Standard delivery: 2-5 business days
  • Express shipping available at checkout
  • Free shipping on orders over $75
  • Tracking number emailed upon shipment

Return Policy

  • 30-day returns on unused parts in original packaging
  • Electrical parts (capacitors, contactors, control boards) are final sale once installed
  • Email info@nationalhvacparts.com to initiate a return
  • Refunds processed within 5-7 business days

Frequently Asked Questions

Does this Contactor fit my Tempstar T4H419GKD100 — 24V Coil | Ships Today?
Yes. This is the factory-specified OEM contactor for the Tempstar T4H419GKD100 — 24V Coil | Ships Today. It is a direct drop-in replacement that fits without modification. Always verify the model number on your equipment nameplate before ordering.
How do I replace the contactor on my Tempstar T4H419GKD100 — 24V Coil | Ships Today?
Difficulty: Medium (30–45 min)
Step 1: Turn off breaker. Step 2: Open condensing unit panel. Step 3: Photograph ALL wiring on the contactor. Step 4: Label each wire with tape. Step 5: Disconnect wires and remove old contactor. Step 6: Mount new contactor, reconnect wires matching your photo. Step 7: Restore power and test.
My AC clicks but the compressor won’t turn on. What’s wrong?
Clicking from the outdoor unit without the compressor starting = worn contactor. The contactor sends power to the compressor. When its contacts are pitted, it clicks but can’t make solid contact. Look for: visible pitting/burn marks on the contactor face, intermittent operation, or buzzing.
Is this contactor compatible with Bryant or Payne too?
Many Tempstar parts are cross-compatible with Bryant and Payne since all three brands are manufactured by Carrier Global Corporation. The same physical part is often used across brand labels with different model numbers. To verify: check your Bryant or Payne equipment service manual for cross-compatible part numbers, or email info@nationalhvacparts.com with your model number.
Should I use OEM or aftermarket for my Tempstar contactor?
OEM recommended for reliability and warranty compatibility. OEM parts match exact factory specifications for proper fit, performance, and safety. While aftermarket alternatives cost less upfront, the risk of improper fit and reduced lifespan usually makes OEM the better value long-term.
How fast does National HVAC Parts ship?
Orders placed before 3:00 PM CST ship the same business day. Standard delivery is 2–5 business days anywhere in the continental United States. Express shipping available at checkout. We ship from Houston, TX to all 50 states. 30-day return policy on all parts.
Home Shop Search Account Cart
Fitment Guaranteed
MR
Mike Rivera
HVAC Parts Specialist — Online