Same-day shipping before 3PM CST · 35,000+ OEM Parts · Texas CMBL & SAM.gov Registered · Government POs Accepted

Menu

Home Shop All Account Cart
Tempstar 1-Pole 30A Contactor 24V for T2A348GKD100 — OEM with Shunt | Ships Today
Tempstar

Tempstar 1-Pole 30A Contactor 24V for T2A348GKD100 — OEM with Shunt | Ships Today

SKU: 1172472-GEN Brand: Tempstar

OEM Guaranteed

Same-Day Ship

30-Day Returns

Secure Checkout

Texas CMBL #19328542014
SAM.gov Registered
Govt POs Accepted

Overview

This OEM 1-pole 30-amp definite-purpose contactor with shunt (part number 1172472) is the switching relay that energizes the compressor and condenser fan on the Tempstar T2A348GKD100. A 24V control signal from the thermostat pulls in the contactor coil, closing the 30A line-voltage contacts. Pitted, welded, or chattering contacts are a leading cause of no-cool calls, hard starts, and burnt control wiring.

Specifications

Spec Value
Part Number 1172472
Type Definite-Purpose Contactor (with Shunt)
Brand Tempstar (ICP / Heil)
Poles 1-Pole
Contact Rating 30A
Coil Voltage 24V
Fit OEM Direct Replacement

Compatibility

Directly fits the Tempstar T2A348GKD100 and the shared ICP/Heil/Comfortmaker condensing platform using the 1172472 contactor. Verify pole count, 30A rating, and 24V coil on your existing part before ordering.

Installation Guide

  1. Safety First — Disconnect power at the disconnect and breaker, then verify zero voltage at the contactor with a multimeter.
  2. Access — Remove the condenser electrical-panel access cover.
  3. Document — Photograph every line, load, and 24V coil wire before disconnecting.
  4. Remove — Disconnect the wiring, unscrew the contactor from the bracket, and lift it out.
  5. Install — Mount the new 1172472 contactor and reconnect each terminal exactly per your photo.
  6. Test — Restore power, call for cooling, and confirm the contactor pulls in cleanly and the contacts close without chatter.

Signs You Need a Replacement

  • Compressor and fan will not start despite a 24V call at the coil.
  • Buzzing, chattering, or visibly pitted/burnt contacts.
  • Contacts welded closed so the unit runs continuously.
  • Intermittent cooling that follows tapping or vibration on the contactor.

Shipping & Returns

Ships same day before 3 PM CST. 30-day returns. Backed by the National HVAC Parts fitment guarantee.

Shipping Information

  • Orders placed before 3PM CST ship same business day
  • Standard delivery: 2-5 business days
  • Express shipping available at checkout
  • Free shipping on orders over $75
  • Tracking number emailed upon shipment

Return Policy

  • 30-day returns on unused parts in original packaging
  • Electrical parts (capacitors, contactors, control boards) are final sale once installed
  • Email info@nationalhvacparts.com to initiate a return
  • Refunds processed within 5-7 business days

Frequently Asked Questions

Does this Contactor fit my Tempstar T2A348GKD100 — OEM with Shunt | Ships Today?
Yes. This is the factory-specified OEM contactor for the Tempstar T2A348GKD100 — OEM with Shunt | Ships Today. It is a direct drop-in replacement that fits without modification. Always verify the model number on your equipment nameplate before ordering.
How do I replace the contactor on my Tempstar T2A348GKD100 — OEM with Shunt | Ships Today?
Difficulty: Medium (30–45 min)
Step 1: Turn off breaker. Step 2: Open condensing unit panel. Step 3: Photograph ALL wiring on the contactor. Step 4: Label each wire with tape. Step 5: Disconnect wires and remove old contactor. Step 6: Mount new contactor, reconnect wires matching your photo. Step 7: Restore power and test.
My AC clicks but the compressor won’t turn on. What’s wrong?
Clicking from the outdoor unit without the compressor starting = worn contactor. The contactor sends power to the compressor. When its contacts are pitted, it clicks but can’t make solid contact. Look for: visible pitting/burn marks on the contactor face, intermittent operation, or buzzing.
Is this contactor compatible with Bryant or Payne too?
Many Tempstar parts are cross-compatible with Bryant and Payne since all three brands are manufactured by Carrier Global Corporation. The same physical part is often used across brand labels with different model numbers. To verify: check your Bryant or Payne equipment service manual for cross-compatible part numbers, or email info@nationalhvacparts.com with your model number.
Should I use OEM or aftermarket for my Tempstar contactor?
OEM recommended for reliability and warranty compatibility. OEM parts match exact factory specifications for proper fit, performance, and safety. While aftermarket alternatives cost less upfront, the risk of improper fit and reduced lifespan usually makes OEM the better value long-term.
How fast does National HVAC Parts ship?
Orders placed before 3:00 PM CST ship the same business day. Standard delivery is 2–5 business days anywhere in the continental United States. Express shipping available at checkout. We ship from Houston, TX to all 50 states. 30-day return policy on all parts.
Home Shop Search Account Cart
Fitment Guaranteed
MR
Mike Rivera
HVAC Parts Specialist — Online