Same-day shipping before 3PM CST · 35,000+ OEM Parts · Texas CMBL & SAM.gov Registered · Government POs Accepted

Menu

Home Shop All Account Cart
Tempstar 1-Pole 25A Contactor for TCH218AKA1 – 24V Coil | Ships Today
Tempstar

Tempstar 1-Pole 25A Contactor for TCH218AKA1 – 24V Coil | Ships Today

SKU: 1050699-GEN Brand: Tempstar

OEM Guaranteed

Same-Day Ship

30-Day Returns

Secure Checkout

Texas CMBL #19328542014
SAM.gov Registered
Govt POs Accepted

Overview

This OEM single-pole definite purpose contactor (part 1050699) is the switching relay that energizes the outdoor unit on the Tempstar TCH218AKA1 heat pump. When the thermostat calls for cooling or heating, the 24V control circuit pulls in the contactor coil, closing the 25A main contacts to feed line voltage to the compressor and condenser fan motor. Pitted, welded, or chattering contacts are one of the most common no-start failures in the field. Symptoms include a unit that won't start, a buzzing or humming contactor that never pulls in, or contacts that stick closed so the compressor never shuts off.

Specifications

Spec Value
Part Number 1050699
Type Single-Pole (1P) Definite Purpose Contactor
Brand Tempstar / ICP / Heil
Contact Rating 25A
Coil Voltage 24V
Poles 1

Compatibility

Direct OEM fit for the Tempstar TCH218AKA1 heat pump. Also used across ICP, Heil, and Comfortmaker condensing units built on the same platform. Verify your existing contactor's amp and coil-voltage rating before ordering.

Installation Guide

  1. Safety First – Disconnect power at the disconnect and breaker, then verify zero voltage with a multimeter.
  2. Access – Remove the outdoor unit service panel.
  3. Document – Photograph all wire positions before disconnecting.
  4. Remove – Note line, load, and 24V coil leads, then transfer wires one at a time from the old contactor.
  5. Install – Mount the new contactor and reconnect each lead per your photo.
  6. Test – Restore power and confirm the contactor pulls in smoothly on a call for cooling.

Signs You Need a Replacement

  • Unit won't start or only starts intermittently
  • Loud buzzing or humming at the contactor
  • Visibly pitted, burned, or welded contacts
  • Compressor runs continuously and won't shut off

Shipping & Returns

Ships same day before 3 PM CST. 30-day returns. Backed by the National HVAC Parts fitment guarantee.

Shipping Information

  • Orders placed before 3PM CST ship same business day
  • Standard delivery: 2-5 business days
  • Express shipping available at checkout
  • Free shipping on orders over $75
  • Tracking number emailed upon shipment

Return Policy

  • 30-day returns on unused parts in original packaging
  • Electrical parts (capacitors, contactors, control boards) are final sale once installed
  • Email info@nationalhvacparts.com to initiate a return
  • Refunds processed within 5-7 business days

Frequently Asked Questions

Does this Contactor fit my Tempstar TCH218AKA1 – 24V Coil | Ships Today?
Yes. This is the factory-specified OEM contactor for the Tempstar TCH218AKA1 – 24V Coil | Ships Today. It is a direct drop-in replacement that fits without modification. Always verify the model number on your equipment nameplate before ordering.
How do I replace the contactor on my Tempstar TCH218AKA1 – 24V Coil | Ships Today?
Difficulty: Medium (30–45 min)
Step 1: Turn off breaker. Step 2: Open condensing unit panel. Step 3: Photograph ALL wiring on the contactor. Step 4: Label each wire with tape. Step 5: Disconnect wires and remove old contactor. Step 6: Mount new contactor, reconnect wires matching your photo. Step 7: Restore power and test.
My AC clicks but the compressor won’t turn on. What’s wrong?
Clicking from the outdoor unit without the compressor starting = worn contactor. The contactor sends power to the compressor. When its contacts are pitted, it clicks but can’t make solid contact. Look for: visible pitting/burn marks on the contactor face, intermittent operation, or buzzing.
Is this contactor compatible with Bryant or Payne too?
Many Tempstar parts are cross-compatible with Bryant and Payne since all three brands are manufactured by Carrier Global Corporation. The same physical part is often used across brand labels with different model numbers. To verify: check your Bryant or Payne equipment service manual for cross-compatible part numbers, or email info@nationalhvacparts.com with your model number.
Should I use OEM or aftermarket for my Tempstar contactor?
OEM recommended for reliability and warranty compatibility. OEM parts match exact factory specifications for proper fit, performance, and safety. While aftermarket alternatives cost less upfront, the risk of improper fit and reduced lifespan usually makes OEM the better value long-term.
How fast does National HVAC Parts ship?
Orders placed before 3:00 PM CST ship the same business day. Standard delivery is 2–5 business days anywhere in the continental United States. Express shipping available at checkout. We ship from Houston, TX to all 50 states. 30-day return policy on all parts.
Home Shop Search Account Cart
Fitment Guaranteed
MR
Mike Rivera
HVAC Parts Specialist — Online