Same-day shipping before 3PM CST · 35,000+ OEM Parts · Texas CMBL & SAM.gov Registered · Government POs Accepted

Menu

Home Shop All Account Cart
Tempstar 1-Pole 25A Contactor for TCH030AKD1 — 24V Coil | Ships Today
Tempstar

Tempstar 1-Pole 25A Contactor for TCH030AKD1 — 24V Coil | Ships Today

SKU: 1050699-GEN Brand: Tempstar

OEM Guaranteed

Same-Day Ship

30-Day Returns

Secure Checkout

Texas CMBL #19328542014
SAM.gov Registered
Govt POs Accepted

Overview

This genuine OEM single-pole contactor (part number 1050699) is the 25-amp, 24V-coil switching relay for the Tempstar TCH030AKD1 condensing unit. The contactor is the heavy-duty switch that delivers line voltage to the compressor and condenser fan motor whenever the 24V coil is energized by a cooling call. Over time the contact points pit, arc, and burn, or the coil itself fails — leaving the outdoor unit silent while the indoor blower still runs, or causing the unit to chatter, buzz, or weld closed and run continuously. A 1-pole contactor switches one leg of power and relies on the always-closed second leg, which is standard on many ICP-family residential condensers. Replacing a worn contactor is one of the most common and inexpensive HVAC service repairs.

Specifications

Spec Value
OEM Part Number 1050699
Type Definite Purpose Contactor, 1-Pole
Brand Tempstar (ICP / Heil)
Contact Rating 25 Amps
Coil Voltage 24V
Poles 1
Fit OEM Direct Replacement

Compatibility

Direct-fit replacement for the Tempstar TCH030AKD1 and the wide range of ICP-family condensers (Heil, Comfortmaker, Arcoaire, KeepRite, Day & Night) that use a 25A, 24V-coil single-pole contactor. Verify amp rating, pole count, and coil voltage against your existing part before installing.

Installation Guide

  1. Safety First — Disconnect power at the outdoor disconnect and verify zero voltage at the contactor terminals with a multimeter.
  2. Access — Remove the condenser service panel to expose the control area.
  3. Document — Photograph every line, load, and 24V coil wire before disconnecting.
  4. Remove — Transfer wires one at a time, or label them, then unscrew the old contactor from its bracket.
  5. Install — Mount the new contactor and reconnect each wire exactly per your photo.
  6. Test — Restore power, call for cooling, and confirm the contactor pulls in cleanly and the compressor and fan start.

Signs You Need a Replacement

  • Outdoor unit won't start, but the indoor blower runs.
  • Buzzing, humming, or chattering from the contactor.
  • Pitted, burned, or welded contact points.
  • Compressor runs nonstop even when the thermostat is satisfied.

Shipping & Returns

Ships same day before 3 PM CST. 30-day returns. Backed by the National HVAC Parts fitment guarantee.

Shipping Information

  • Orders placed before 3PM CST ship same business day
  • Standard delivery: 2-5 business days
  • Express shipping available at checkout
  • Free shipping on orders over $75
  • Tracking number emailed upon shipment

Return Policy

  • 30-day returns on unused parts in original packaging
  • Electrical parts (capacitors, contactors, control boards) are final sale once installed
  • Email info@nationalhvacparts.com to initiate a return
  • Refunds processed within 5-7 business days

Frequently Asked Questions

Does this Contactor fit my Tempstar TCH030AKD1 — 24V Coil | Ships Today?
Yes. This is the factory-specified OEM contactor for the Tempstar TCH030AKD1 — 24V Coil | Ships Today. It is a direct drop-in replacement that fits without modification. Always verify the model number on your equipment nameplate before ordering.
How do I replace the contactor on my Tempstar TCH030AKD1 — 24V Coil | Ships Today?
Difficulty: Medium (30–45 min)
Step 1: Turn off breaker. Step 2: Open condensing unit panel. Step 3: Photograph ALL wiring on the contactor. Step 4: Label each wire with tape. Step 5: Disconnect wires and remove old contactor. Step 6: Mount new contactor, reconnect wires matching your photo. Step 7: Restore power and test.
My AC clicks but the compressor won’t turn on. What’s wrong?
Clicking from the outdoor unit without the compressor starting = worn contactor. The contactor sends power to the compressor. When its contacts are pitted, it clicks but can’t make solid contact. Look for: visible pitting/burn marks on the contactor face, intermittent operation, or buzzing.
Is this contactor compatible with Bryant or Payne too?
Many Tempstar parts are cross-compatible with Bryant and Payne since all three brands are manufactured by Carrier Global Corporation. The same physical part is often used across brand labels with different model numbers. To verify: check your Bryant or Payne equipment service manual for cross-compatible part numbers, or email info@nationalhvacparts.com with your model number.
Should I use OEM or aftermarket for my Tempstar contactor?
OEM recommended for reliability and warranty compatibility. OEM parts match exact factory specifications for proper fit, performance, and safety. While aftermarket alternatives cost less upfront, the risk of improper fit and reduced lifespan usually makes OEM the better value long-term.
How fast does National HVAC Parts ship?
Orders placed before 3:00 PM CST ship the same business day. Standard delivery is 2–5 business days anywhere in the continental United States. Express shipping available at checkout. We ship from Houston, TX to all 50 states. 30-day return policy on all parts.
Home Shop Search Account Cart
Fitment Guaranteed
MR
Mike Rivera
HVAC Parts Specialist — Online