Same-day shipping before 3PM CST · 35,000+ OEM Parts · Texas CMBL & SAM.gov Registered · Government POs Accepted

Menu

Home Shop All Account Cart
Tempstar 1-Pole 25A Contactor for TCA430AKC3 — 24V Coil | Ships Today
Tempstar

Tempstar 1-Pole 25A Contactor for TCA430AKC3 — 24V Coil | Ships Today

SKU: 1050699-GEN Brand: Tempstar

OEM Guaranteed

Same-Day Ship

30-Day Returns

Secure Checkout

Texas CMBL #19328542014
SAM.gov Registered
Govt POs Accepted

Overview

This genuine OEM single-pole definite purpose contactor (part number 1050699) is the primary switching relay for the Tempstar TCA430AKC3 condensing unit. Rated 25 amps with a 24-volt coil, it closes to feed the compressor and condenser fan motor whenever the thermostat calls for cooling. A failing contactor is one of the most common causes of a no-cool condenser: pitted or welded contacts interrupt current, a burned coil stops pulling the armature in, and low control voltage produces a steady chatter. Swapping in a fresh contactor restores dependable starts and stops the contact arcing that shortens compressor life.

Specifications

Spec Value
Part Number 1050699
Type Single-Pole (1P) Definite Purpose Contactor
Brand Tempstar (ICP / Heil)
Contact Rating 25 Amps
Coil Voltage 24 VAC
Poles 1
Fits Model TCA430AKC3
Fitment OEM Replacement

Compatibility

Designed for the Tempstar TCA430AKC3 air conditioning condenser and compatible across ICP/Heil TCA430-series units that use the same 24V control circuit. Confirm pole count, amperage, and coil voltage against your existing part before installing.

Installation Guide

  1. Safety First — Disconnect power at the disconnect and breaker, then verify zero voltage with a multimeter across the line terminals.
  2. Access — Remove the condenser service panel to reach the contactor.
  3. Document — Photograph every wire and terminal before disconnecting anything.
  4. Remove — Label and disconnect the line, load, and 24V coil leads, then unfasten the old contactor from its bracket.
  5. Install — Mount the new contactor, reconnect each lead per your photo, and confirm the coil terminals match.
  6. Test — Reinstall the panel, restore power, and verify the compressor and fan engage cleanly on a cooling call.

Signs You Need a Replacement

  • Condenser won't start when the thermostat calls for cooling
  • Buzzing, chattering, or humming at the contactor
  • Pitted, burned, or welded contact surfaces
  • Coil reads open or fails to pull in

Shipping & Returns

Ships same day before 3 PM CST. 30-day returns. Backed by the National HVAC Parts fitment guarantee.

Shipping Information

  • Orders placed before 3PM CST ship same business day
  • Standard delivery: 2-5 business days
  • Express shipping available at checkout
  • Free shipping on orders over $75
  • Tracking number emailed upon shipment

Return Policy

  • 30-day returns on unused parts in original packaging
  • Electrical parts (capacitors, contactors, control boards) are final sale once installed
  • Email info@nationalhvacparts.com to initiate a return
  • Refunds processed within 5-7 business days

Frequently Asked Questions

Does this Contactor fit my Tempstar TCA430AKC3 — 24V Coil | Ships Today?
Yes. This is the factory-specified OEM contactor for the Tempstar TCA430AKC3 — 24V Coil | Ships Today. It is a direct drop-in replacement that fits without modification. Always verify the model number on your equipment nameplate before ordering.
How do I replace the contactor on my Tempstar TCA430AKC3 — 24V Coil | Ships Today?
Difficulty: Medium (30–45 min)
Step 1: Turn off breaker. Step 2: Open condensing unit panel. Step 3: Photograph ALL wiring on the contactor. Step 4: Label each wire with tape. Step 5: Disconnect wires and remove old contactor. Step 6: Mount new contactor, reconnect wires matching your photo. Step 7: Restore power and test.
My AC clicks but the compressor won’t turn on. What’s wrong?
Clicking from the outdoor unit without the compressor starting = worn contactor. The contactor sends power to the compressor. When its contacts are pitted, it clicks but can’t make solid contact. Look for: visible pitting/burn marks on the contactor face, intermittent operation, or buzzing.
Is this contactor compatible with Bryant or Payne too?
Many Tempstar parts are cross-compatible with Bryant and Payne since all three brands are manufactured by Carrier Global Corporation. The same physical part is often used across brand labels with different model numbers. To verify: check your Bryant or Payne equipment service manual for cross-compatible part numbers, or email info@nationalhvacparts.com with your model number.
Should I use OEM or aftermarket for my Tempstar contactor?
OEM recommended for reliability and warranty compatibility. OEM parts match exact factory specifications for proper fit, performance, and safety. While aftermarket alternatives cost less upfront, the risk of improper fit and reduced lifespan usually makes OEM the better value long-term.
How fast does National HVAC Parts ship?
Orders placed before 3:00 PM CST ship the same business day. Standard delivery is 2–5 business days anywhere in the continental United States. Express shipping available at checkout. We ship from Houston, TX to all 50 states. 30-day return policy on all parts.