Same-day shipping before 3PM CST · 35,000+ OEM Parts · Texas CMBL & SAM.gov Registered · Government POs Accepted

Menu

Home Shop All Account Cart
Tempstar 1-Pole 25A Contactor for TCA242AKC4 — 24V Coil | Ships Today
Tempstar

Tempstar 1-Pole 25A Contactor for TCA242AKC4 — 24V Coil | Ships Today

SKU: 1050699-GEN Brand: Tempstar

OEM Guaranteed

Same-Day Ship

30-Day Returns

Secure Checkout

Texas CMBL #19328542014
SAM.gov Registered
Govt POs Accepted

Overview

This OEM single-pole contactor (part number 1050699) is the switching relay that controls power to the compressor and condenser fan in your Tempstar TCA242AKC4 condensing unit. Rated for 25 amps with a 24-volt control coil, it energizes the line-voltage load whenever the thermostat calls for cooling. When a contactor fails, the most common symptoms are an outdoor unit that hums but won't start, contacts that weld shut and keep the compressor running, pitted or burned contact surfaces, or a coil that no longer pulls in. Replacing a worn contactor restores reliable, safe switching and prevents premature compressor wear.

Specifications

Spec Value
Part Number 1050699
Type Definite Purpose Contactor, 1-Pole
Brand Tempstar
Contact Rating 25A
Coil Voltage 24V
Poles 1
Fitment OEM

Compatibility

This contactor is the factory-specified switching component for the Tempstar TCA242AKC4 and shares the same 1050699 part across closely related ICP / Tempstar / Heil condensing units. Always confirm your unit calls for a 1-pole, 25A, 24V-coil contactor before ordering.

Installation Guide

  1. Safety First — Disconnect power at the outdoor disconnect and breaker, then verify zero voltage across the line terminals with a multimeter.
  2. Access — Remove the service panel from the condensing unit to expose the contactor.
  3. Document — Photograph all wire connections before disconnecting anything.
  4. Remove — Label and disconnect the line, load, and 24V coil wires, then unscrew the old contactor from its bracket.
  5. Install — Mount the new contactor in the same orientation and reconnect each wire exactly as shown in your photo.
  6. Test — Restore power, call for cooling, and confirm the contactor pulls in cleanly and the compressor and fan start.

Signs You Need a Replacement

  • Outdoor unit hums or buzzes but the compressor won't start.
  • Visibly pitted, burned, or melted contact surfaces.
  • Compressor keeps running after the thermostat is satisfied (welded contacts).
  • Chattering or no pull-in when the 24V coil is energized.

Shipping & Returns

Ships same day before 3 PM CST. 30-day returns. Backed by the National HVAC Parts fitment guarantee.

Shipping Information

  • Orders placed before 3PM CST ship same business day
  • Standard delivery: 2-5 business days
  • Express shipping available at checkout
  • Free shipping on orders over $75
  • Tracking number emailed upon shipment

Return Policy

  • 30-day returns on unused parts in original packaging
  • Electrical parts (capacitors, contactors, control boards) are final sale once installed
  • Email info@nationalhvacparts.com to initiate a return
  • Refunds processed within 5-7 business days

Frequently Asked Questions

Does this Contactor fit my Tempstar TCA242AKC4 — 24V Coil | Ships Today?
Yes. This is the factory-specified OEM contactor for the Tempstar TCA242AKC4 — 24V Coil | Ships Today. It is a direct drop-in replacement that fits without modification. Always verify the model number on your equipment nameplate before ordering.
How do I replace the contactor on my Tempstar TCA242AKC4 — 24V Coil | Ships Today?
Difficulty: Medium (30–45 min)
Step 1: Turn off breaker. Step 2: Open condensing unit panel. Step 3: Photograph ALL wiring on the contactor. Step 4: Label each wire with tape. Step 5: Disconnect wires and remove old contactor. Step 6: Mount new contactor, reconnect wires matching your photo. Step 7: Restore power and test.
My AC clicks but the compressor won’t turn on. What’s wrong?
Clicking from the outdoor unit without the compressor starting = worn contactor. The contactor sends power to the compressor. When its contacts are pitted, it clicks but can’t make solid contact. Look for: visible pitting/burn marks on the contactor face, intermittent operation, or buzzing.
Is this contactor compatible with Bryant or Payne too?
Many Tempstar parts are cross-compatible with Bryant and Payne since all three brands are manufactured by Carrier Global Corporation. The same physical part is often used across brand labels with different model numbers. To verify: check your Bryant or Payne equipment service manual for cross-compatible part numbers, or email info@nationalhvacparts.com with your model number.
Should I use OEM or aftermarket for my Tempstar contactor?
OEM recommended for reliability and warranty compatibility. OEM parts match exact factory specifications for proper fit, performance, and safety. While aftermarket alternatives cost less upfront, the risk of improper fit and reduced lifespan usually makes OEM the better value long-term.
How fast does National HVAC Parts ship?
Orders placed before 3:00 PM CST ship the same business day. Standard delivery is 2–5 business days anywhere in the continental United States. Express shipping available at checkout. We ship from Houston, TX to all 50 states. 30-day return policy on all parts.
Home Shop Search Account Cart
Fitment Guaranteed
MR
Mike Rivera
HVAC Parts Specialist — Online