This genuine OEM single-pole contactor (part number 1050699) is the factory replacement for the Tempstar TCA218AKA5 condensing unit. Rated 25 amps with a 24-volt coil, the contactor is the electrically operated switch that energizes the compressor and condenser fan circuit whenever the thermostat calls for cooling. A 24V signal from the control board or transformer pulls in the contactor's armature, closing the high-voltage contacts that power the outdoor unit. Contactors are one of the most common failure points in any air conditioner — the contacts pit, burn, and weld over thousands of cycles, while the coil can open or buzz. Symptoms include a unit that won't start, a chattering or humming sound, or a compressor that runs continuously because the contacts have welded shut.

Specifications

Spec Value
Part Number 1050699
Type Definite Purpose Contactor, 1-Pole
Brand Tempstar
Contact Rating 25 Amps
Coil Voltage 24 VAC
Poles 1
Fit OEM exact replacement

Compatibility

Direct factory-correct fit for the Tempstar TCA218AKA5 air conditioner / heat pump condenser. The same 1050699 contactor is shared across many ICP / Heil / Comfortmaker TCA218-family units using a 1-pole, 25A, 24V coil configuration. Verify your coil voltage and pole count against the old contactor before installing.

Installation Guide

  1. Safety First — Disconnect power at the outdoor disconnect and verify zero voltage with a multimeter on the line terminals.
  2. Access — Remove the service panel from the condenser cabinet.
  3. Document — Photograph all line, load, and coil wiring before disconnecting.
  4. Remove — Transfer wires one at a time, or label each, then unscrew and lift out the old contactor.
  5. Install — Mount the new contactor, reconnect every wire per your photo, and confirm the 24V coil leads are correct.
  6. Test — Restore power, call for cooling, and verify the contactor pulls in cleanly and the compressor and fan start.

Signs You Need a Replacement

  • Outdoor unit hums or chatters but won't start
  • Burned, pitted, or melted contacts visible on the old contactor
  • Compressor runs nonstop (contacts welded closed)
  • Coil is open or won't pull in the armature on a 24V call

Shipping & Returns

Ships same day before 3 PM CST. 30-day returns. Backed by the National HVAC Parts fitment guarantee.

Shipping Information

  • Orders placed before 3PM CST ship same business day
  • Standard delivery: 2-5 business days
  • Express shipping available at checkout
  • Free shipping on orders over $75
  • Tracking number emailed upon shipment

Return Policy

  • 30-day returns on unused parts in original packaging
  • Electrical parts (capacitors, contactors, control boards) are final sale once installed
  • Email info@nationalhvacparts.com to initiate a return
  • Refunds processed within 5-7 business days

Frequently Asked Questions

Does this Contactor fit my Tempstar TCA218AKA5 — 24V Coil | Ships Today?
Yes. This is the factory-specified OEM contactor for the Tempstar TCA218AKA5 — 24V Coil | Ships Today. It is a direct drop-in replacement that fits without modification. Always verify the model number on your equipment nameplate before ordering.
How do I replace the contactor on my Tempstar TCA218AKA5 — 24V Coil | Ships Today?
Difficulty: Medium (30–45 min)
Step 1: Turn off breaker. Step 2: Open condensing unit panel. Step 3: Photograph ALL wiring on the contactor. Step 4: Label each wire with tape. Step 5: Disconnect wires and remove old contactor. Step 6: Mount new contactor, reconnect wires matching your photo. Step 7: Restore power and test.
My AC clicks but the compressor won’t turn on. What’s wrong?
Clicking from the outdoor unit without the compressor starting = worn contactor. The contactor sends power to the compressor. When its contacts are pitted, it clicks but can’t make solid contact. Look for: visible pitting/burn marks on the contactor face, intermittent operation, or buzzing.
Is this contactor compatible with Bryant or Payne too?
Many Tempstar parts are cross-compatible with Bryant and Payne since all three brands are manufactured by Carrier Global Corporation. The same physical part is often used across brand labels with different model numbers. To verify: check your Bryant or Payne equipment service manual for cross-compatible part numbers, or email info@nationalhvacparts.com with your model number.
Should I use OEM or aftermarket for my Tempstar contactor?
OEM recommended for reliability and warranty compatibility. OEM parts match exact factory specifications for proper fit, performance, and safety. While aftermarket alternatives cost less upfront, the risk of improper fit and reduced lifespan usually makes OEM the better value long-term.
How fast does National HVAC Parts ship?
Orders placed before 3:00 PM CST ship the same business day. Standard delivery is 2–5 business days anywhere in the continental United States. Express shipping available at checkout. We ship from Houston, TX to all 50 states. 30-day return policy on all parts.
Home Shop Search Account Cart
Fitment Guaranteed
MR
Mike Rivera
HVAC Parts Specialist — Online