OEM Guaranteed
Same-Day Ship
30-Day Returns
Secure Checkout
This genuine OEM 1/5 HP condenser fan motor drives the outdoor fan on the Tempstar T4H448GKD200 heat pump, pulling air across the coil to release heat during cooling and absorb it during heating. When this motor fails, the unit loses its ability to reject heat, causing high head pressure, compressor overheating, and eventual safety lockout. Typical symptoms include an outdoor fan that will not spin, a fan that hums but does not start, a blade that spins freely only when pushed by hand, and a hot or noisy motor with worn bearings. Running a system with a failed condenser fan motor risks a far costlier compressor failure, so prompt replacement is essential.
| Spec | Value |
|---|---|
| OEM Part Number | 1177593 |
| Type | Condenser Fan Motor |
| Brand | Tempstar |
| Horsepower | 1/5 HP |
| Application | Condenser Fan / Heat Pump |
| Fitment | OEM Replacement |
Direct OEM replacement for the Tempstar T4H448GKD200 heat pump and shared across matching ICP-built condensing units including Heil and Comfortmaker. Confirm horsepower, rotation, and shaft size against your existing motor before ordering.
Ships same day before 3 PM CST. 30-day returns. Backed by the National HVAC Parts fitment guarantee.