IMAGE COMING SOON
OEM Guaranteed
Same-Day Ship
30-Day Returns
Secure Checkout
The genuine OEM Lennox 98G47 thermal cut-off is a safety limit device that protects your furnace from dangerous overheating. It continuously senses temperature in the heat-exchanger or burner area and instantly interrupts the circuit if heat climbs past a safe threshold — shutting down the burners to prevent heat-exchanger damage, component failure, and fire risk.
Common failure symptoms: the furnace short-cycles or won't fire on a heat call, burners ignite then drop out repeatedly, the system trips to a lockout or displays a limit-fault code, or the unit stays cold despite a working igniter and gas supply. A cut-off can also fail from age, nuisance tripping caused by restricted airflow, or a dirty filter.
Why OEM matters: this is a safety-critical component with a precise trip temperature and reset rating specified for your Lennox model. A substitute with the wrong setpoint may trip early, fail to trip when needed, or not seat correctly. The OEM Lennox 98G47 guarantees the exact temperature calibration and mounting fit your equipment requires for safe, reliable protection.