IMAGE COMING SOON
OEM Guaranteed
Same-Day Ship
30-Day Returns
Secure Checkout
The genuine OEM Lennox 11U64 pressure switch with mounting bracket is a critical safety control that verifies proper airflow and venting before allowing the ignition or operating sequence to proceed on your Lennox equipment. It monitors pressure differential and prevents the system from firing under unsafe conditions, protecting both the equipment and your home. The included bracket ensures the switch is mounted at the correct position and orientation for accurate readings.
When a pressure switch fails or drifts out of calibration, you may experience a furnace that ignites and then shuts down, a system that will not start at all, repeated lockouts, or fault codes indicating a pressure switch error. Blocked hoses, a stuck diaphragm, or a switch that no longer closes at the rated point are the most common culprits.
The OEM 11U64 is calibrated to the precise pressure setpoint specified for your Lennox system, so it trips at exactly the right threshold. Generic substitutes with the wrong setpoint can cause nuisance shutdowns or, worse, fail to protect the unit. Restore safe, reliable operation with the correct factory part and bracket.