IMAGE COMING SOON
OEM Guaranteed
Same-Day Ship
30-Day Returns
Secure Checkout
The genuine OEM Lennox 14A45 pressure switch is a safety control that confirms proper combustion airflow and venting before your Lennox furnace is allowed to ignite. It senses the negative pressure created by the draft inducer motor and closes only when adequate airflow is verified — ensuring flue gases are being safely vented and preventing ignition under blocked-vent conditions.
Common failure symptoms: the furnace failing to ignite, the inducer running but no burner light-off, repeated lockouts, or an error code indicating an open pressure switch. Failures are often caused by a cracked pressure hose, blocked vent or condensate drain, a weak inducer, or a switch whose diaphragm has fatigued and no longer actuates at the correct setpoint.
Why OEM matters: the Lennox 14A45 is factory-set to the precise pressure threshold your furnace model requires. A switch with the wrong setpoint can allow unsafe operation or cause persistent nuisance lockouts. Installing the factory-specified part ensures accurate draft proving, dependable safety response, and full compatibility with your Lennox equipment.