OEM Guaranteed
Same-Day Ship
30-Day Returns
Secure Checkout
The genuine OEM Lennox Y4625 contactor is the electrical switch that delivers high-voltage power to your outdoor unit's compressor and condenser fan motor. When your thermostat calls for cooling, the low-voltage control circuit energizes the contactor coil, closing the contacts and powering the condensing unit. It is a critical, high-cycle component in every Lennox air conditioner and heat pump.
Common failure symptoms include an outdoor unit that hums but won't start, a fan and compressor that won't run, chattering or buzzing at the contactor, pitted or burned contacts, or a condenser that stays running even after the thermostat is satisfied — a sign of welded contacts. Ants, corrosion, and normal arcing wear are frequent causes of contactor failure.
Why OEM matters: the Y4625 is matched to your Lennox unit's coil voltage, contact rating, and physical mounting. Using the correct factory contactor ensures the amperage rating handles your compressor's inrush current, the coil energizes on the proper control voltage, and the part drops cleanly into the existing bracket for a fast, safe installation.