OEM Guaranteed
Same-Day Ship
30-Day Returns
Secure Checkout
The Goodman 0130F00070 Pressure Switch is a genuine OEM venting safety control for the ACVM961005DXAA modulating gas furnace and compatible Goodman and Amana models. The pressure switch monitors the negative pressure created by the draft inducer motor and only closes — allowing the ignition sequence to proceed — when proper venting airflow is confirmed. A blocked flue, failing inducer, or cracked hose will keep the switch open, preventing unsafe combustion. A worn or out-of-calibration switch is a leading cause of no-heat and inducer lockout faults.
Pressure-switch setpoints must match the furnace's inducer and venting design exactly. OEM 0130F00070 is calibrated to the correct trip pressure for this model. Generic switches with an incorrect setpoint can either block normal operation or, worse, allow ignition with inadequate venting — a safety risk. OEM is the right choice for combustion-safety parts.
Easy (2/5). Power off, photograph wiring and hose routing, remove the mounting screws, transfer the tubing and leads, and mount the new switch. About 15–20 minutes. Confirm the hose is clear and seated.