The Goodman 0130F00070 is a genuine OEM air-proving pressure switch engineered for the Goodman/Amana ACVC950915DXAD 95% AFUE gas furnace. This safety control monitors negative pressure (vacuum) in the venting system and confirms the inducer motor is moving combustion gases before the control board allows ignition. A failed or out-of-spec switch is a common cause of furnaces that lock out, short-cycle, or throw a pressure-switch fault code.
This is a factory OEM Goodman component built to the exact trip-point pressure (W.C.) the furnace control board expects. Generic substitutes often carry an approximate setpoint that can cause nuisance lockouts in two-stage furnaces. We recommend OEM for guaranteed staging accuracy and warranty compliance.
Disconnect power, remove the hose and the two spade connectors, unscrew the switch, and reverse. Most homeowners with basic tools complete this in 15–20 minutes. Always verify vent tubing is clear of condensate before replacing.