OEM Guaranteed
Same-Day Ship
30-Day Returns
Secure Checkout
The Goodman 0130F00100 is a genuine OEM air pressure switch for the ACVC950714CXBA high-efficiency condensing gas furnace and compatible Goodman/Amana models. On two-stage and high-efficiency platforms the pressure switch (or switch assembly) confirms that the inducer motor has established the correct venting draft for the active firing rate before the board energizes the igniter and gas valve. Without a proven draft signal, the furnace stays locked out for safety — a common reason a high-efficiency unit clicks but never lights.
This higher-capacity switch is calibrated to a specific set point and port layout for the furnace's staged operation. The genuine OEM 0130F00100 guarantees the correct trip pressure for each firing stage. Generic alternatives rarely match staged set points precisely, causing intermittent lockouts that are difficult to diagnose. For reliable combustion safety, install OEM.
Easy (2 of 5). Roughly 15–20 minutes. Disconnect power, document and transfer each wire lead and sensing hose exactly, then mount the new switch in the original orientation. Inspect the inducer, vent, and condensate trap so the replacement isn't masking an underlying draft restriction. Always confirm model/serial compatibility before installing.