OEM Guaranteed
Same-Day Ship
30-Day Returns
Secure Checkout
The Goodman 0130F00070 Pressure Switch is a genuine OEM replacement for the ACVC950714CXAB condensing gas furnace. This air-proving switch confirms that the draft inducer is moving combustion gases through the heat exchanger and vent before allowing ignition. If venting is blocked, the inducer is weak, or condensate has clogged the trap, the switch stays open and the furnace locks out — a common cause of intermittent no-heat calls and ignition lockout faults.
The OEM 0130F00070 is calibrated to the exact 'water column' (W.C.) trip setpoint your furnace's control sequence expects. Generic switches with different pressure ratings will either nuisance-trip or fail to prove draft properly, producing erratic operation. For a safety-critical air-proving device, OEM calibration matters.
Moderate (3/5). Power down the furnace, label and transfer the pressure tubing and wiring, then mount the new switch. Inspect the hose and condensate trap for blockage while you're in there.