OEM Guaranteed
Same-Day Ship
30-Day Returns
Secure Checkout
The Goodman 0130F00508 Pressure Switch is a genuine OEM air-proving safety control for the ACVC80603BXCA gas furnace and compatible Goodman/Amana models. It senses negative pressure created by the draft inducer and must close to confirm proper combustion airflow and venting before the control board allows ignition. A failed or out-of-spec switch is a leading cause of no-heat calls, inducer running with no ignition, and pressure-switch fault codes.
This genuine OEM switch is set to the precise pressure trip point (inches of water column) engineered for your furnace and inducer. Generic switches with a mismatched setpoint can prevent ignition or, dangerously, close when draft is insufficient. OEM guarantees correct calibration, hose-port fit, and warranty compliance.
Moderate (2/5). Shut off power, photograph wiring, transfer the sensing hose and electrical leads to the new switch, and remount. Inspect the hose and inducer for blockages before replacing, since those often cause apparent switch failures.