OEM Guaranteed
Same-Day Ship
30-Day Returns
Secure Checkout
The Goodman B1370150 pressure switch is the genuine OEM -0.85" WC normally-open draft-proving switch for ADS81155CXA gas furnaces. Sensing vacuum from the draft inducer, it closes only when adequate combustion airflow is present, allowing the ignition sequence to proceed. A failed switch, blocked vent, or weak inducer leaves the contacts open, producing a pressure-switch lockout and no heat — a fresh OEM switch with the correct -0.85" setpoint restores safe, reliable firing.
Pressure-switch calibration is matched to each furnace's inducer and venting. The OEM Goodman switch is set to the exact -0.85" WC trip point on the rating plate. Generic switches at the wrong setpoint cause false lockouts or, worse, allow firing without proper draft. For this safety circuit, OEM is the correct choice.
Easy — one or two screws, a sensing hose, and spade terminals. Power down, transfer the tubing and wires, and confirm the setpoint stamp matches -0.85". If the new switch still won't close, inspect the inducer, hose, and vent for restriction.