OEM Guaranteed
Same-Day Ship
30-Day Returns
Secure Checkout
The Goodman 0130F00070 is a genuine OEM air-proving pressure switch built for the ACVC950915DXBA two-stage, high-efficiency condensing furnace. It verifies that the inducer motor is producing adequate draft before the control board allows the gas valve to open, making it a critical combustion-safety component.
When this switch fails or its hose collects condensate, the furnace typically refuses to light, flashes a pressure-switch fault code, or short-cycles the inducer. Installing the correct OEM switch restores the exact factory pressure setpoint so the furnace sequences normally.
OEM vs. Generic: Pressure switches are calibrated in inches of water column ("WC) to a tight tolerance. The OEM 0130F00070 ships with the precise setpoint for this furnace; a generic switch with the wrong rating can nuisance-trip in cold weather or, worse, fail to prove a blocked vent. For combustion safety, OEM is the right choice.
Installation difficulty: Easy to moderate. One or two screws, a single rubber hose, and spade terminals — about 15–20 minutes. Inspect the pressure hose and inducer port for condensate or blockage while you are in there, since debris is a frequent cause of switch faults. Shut off power and gas before servicing.