Trane Furnace Error Codes — Complete Guide

Every documented Trane furnace error code with causes, fixes, and the parts you may need. Also covers: American Standard.

How to read Trane error codes:
Trane and American Standard furnaces use a flash count system. Count the number of times the red LED on the control board flashes in each cycle, separated by a pause. For example: 3 flashes, pause, 3 flashes = Code 3. Open the lower furnace panel to view the LED.

All Trane Error Codes

Slow Flashing (1 per 2 sec)

Normal - No Call for Heat

The furnace is in standby mode. No thermostat demand. The system is operating normally and waiting for a heat call.

DIY check: No action needed. This is the normal idle state.

Fast Flashing (2 per sec)

Normal - Call for Heat Active

The thermostat is calling for heat and the furnace is responding. Normal operating sequence in progress.

DIY check: No action needed if the furnace is producing heat normally.

Continuous ON (solid light)

Control Board Failure

The LED is on continuously without blinking. The control board has an internal failure and cannot operate the furnace.

DIY check: Power cycle the furnace (off for 30 seconds, then on). If the LED stays solid, the control board needs replacement.

Common part needed: Shop Control Board →

Continuous OFF (no light)

No Power to Board

The LED is completely off. No power is reaching the control board.

DIY check: Check: furnace switch is ON, breaker is not tripped, door safety switch is engaged (furnace door fully closed). Check the 3A or 5A fuse on the board. Check the transformer output (should read ~24VAC).

Common part needed: Shop Transformer →

2 Flashes

System Lockout

The furnace has exceeded its maximum number of ignition retries or recycles and has locked out. It will not attempt to restart until manually reset.

DIY check: Power cycle the furnace to clear the lockout. If it locks out again within a few cycles, the underlying ignition problem must be fixed first (usually a flame sensor, igniter, or gas supply issue).

Common part needed: Shop Igniter →

3 Flashes

Pressure Switch Error

The vent pressure switch did not close or reopened during operation. The inducer motor may run but the burners will not ignite.

DIY check: Check: clogged condensate drain (most common on 90%+ units), blocked exhaust vent, cracked pressure hose, weak inducer motor. Clear the condensate trap first.

Common part needed: Shop Pressure Switch →

4 Flashes

Open High Temperature Limit

The high-temperature limit switch has opened due to overheating. The blower may run continuously to cool the heat exchanger.

DIY check: Check air filter (dirty filter is the #1 cause), open all supply registers, check the blower wheel for dust buildup, ensure the A-coil is not iced or dirty.

Common part needed: Shop Fan Motor →

5 Flashes

Flame Sensed Without Gas Valve

The flame sensor is detecting a flame signal when the gas valve should be closed. This could indicate a leaking gas valve (serious safety issue) or a faulty flame sensor.

DIY check: Turn off the furnace and gas supply immediately. Call a licensed technician. Do not attempt to diagnose a potential gas leak yourself.

Common part needed: Shop Gas Valve →

6 Flashes

Power Reversed / Poor Grounding

The 115VAC line and neutral are reversed at the furnace connection, or the furnace does not have a proper ground. This can cause erratic operation and is a shock hazard.

DIY check: Check the outlet or junction box wiring. Hot (black) and neutral (white) may be swapped. Verify with a voltmeter. Also check that the ground wire is properly connected.

7 Flashes

Gas Valve Circuit Error

The control board detected a fault in the gas valve circuit. The gas valve is not responding correctly to the board's commands.

DIY check: Check: gas valve wiring connections, gas valve coil resistance (compare to specs). If the valve is clicking but not opening, it may be stuck internally. Gas valve replacement typically requires a licensed technician.

Common part needed: Shop Gas Valve →

8 Flashes

Low Flame Signal

The flame sensor is detecting a flame but the signal is weak (typically below 1 microamp). The furnace may light but shut down after 10-30 seconds.

DIY check: Clean the flame sensor with fine-grit emery cloth or steel wool. Check the sensor wire for damage or poor connection. If cleaning does not fix it, the sensor or its wire may need replacement.

Common part needed: Shop Flame Sensor →

9 Flashes

High Stage Pressure Switch Error

On two-stage furnaces, the high-fire pressure switch did not close or reopened. The furnace may operate on low fire only.

DIY check: Same checks as 3 flashes but specific to the high-stage switch. Check vent sizing for the high-fire BTU rating. The high-stage switch requires more negative pressure to close.

Common part needed: Shop Pressure Switch →

10 Flashes

Line Polarity / Ground Fault

A ground fault or wiring polarity issue has been detected. Similar to 6 flashes but on some newer Trane models indicates a more specific ground fault condition.

DIY check: Verify proper wiring polarity and ground connection at the furnace. Check for any wires touching the cabinet or chassis.

When to call a technician

If the same code keeps coming back after you have addressed the obvious cause (dirty filter, flame sensor, etc.), or if you smell gas, see burn marks, or the furnace will not come out of lockout after a power cycle, call a licensed HVAC technician. Electrical and gas work carries real safety risk.

FAQ

How do I reset my Trane furnace after an error code?
Turn the furnace power off at the switch or breaker for 30 seconds, then turn it back on. The control board will clear the lockout and attempt to restart. If the same code returns, the underlying problem has not been fixed.
My Trane furnace shows no LED light at all
No light means no power to the control board. Check: the furnace switch is on, the breaker is not tripped, and the door safety switch is engaged (the furnace door must be fully closed). If all three check out, the control board or transformer may have failed.
Can I fix Trane error codes myself?
Many codes point to simple fixes: replacing a dirty filter (codes related to overheating), cleaning the flame sensor (codes related to flame proving), or clearing a blocked condensate drain (pressure switch codes). Anything involving gas lines, wiring, or the heat exchanger should be left to a licensed technician.