Ruud Furnace Error Codes — Complete Guide

Every documented Ruud furnace error code with causes, fixes, and the parts you may need. Also covers: Ruud.

How to read Ruud error codes:
Ruud and Ruud furnaces use a flash count system. Count the number of times the red LED blinks, separated by a 2-second pause between cycles. 1 flash = Code 1, etc. Open the lower furnace panel to view the LED on the control board.

All Ruud Error Codes

Steady ON

Replace Control Board

Internal control board failure. The board cannot operate the furnace.

DIY check: Power cycle first. If steady ON persists, the control board needs replacement.

Common part needed: Shop Control Board →

Steady OFF

Check Power

No power reaching the control board.

DIY check: Check breaker, furnace switch, door switch, board fuse, and transformer.

Common part needed: Shop Transformer →

1 Flash

Ignition Lockout

The furnace failed to ignite after maximum retries. System locked out.

DIY check: Power cycle to reset. Check gas supply, igniter condition, and flame sensor cleanliness.

Common part needed: Shop Igniter →

2 Flashes

Pressure Switch Stuck Closed

Pressure switch is closed before inducer operation. Switch may be stuck or hose may have water in it.

DIY check: Tap the pressure switch gently. Check for water in the hose. Replace if it sticks repeatedly.

Common part needed: Shop Pressure Switch →

3 Flashes

Pressure Switch Open

Pressure switch did not close after inducer started. Most common Ruud error code.

DIY check: Check condensate drain, vent blockage, pressure hose, inducer motor. Clear the trap first.

Common part needed: Shop Pressure Switch →

4 Flashes

Flame Rollout Switch Open

The flame rollout safety switch tripped. Flame was detected outside the combustion chamber.

DIY check: Do NOT simply reset and run. Have a technician inspect the heat exchanger and burners. Could indicate a cracked heat exchanger.

5 Flashes

Low Flame Signal

Flame is present but the sensor reading is weak (below ~1.5 microamps).

DIY check: Clean the flame sensor with emery cloth. Check the sensor wire connection. Replace the sensor if cleaning does not improve the signal.

Common part needed: Shop Flame Sensor →

6 Flashes

115V Power Reversed

Line and neutral are reversed at the furnace.

DIY check: Check and correct the wiring polarity at the furnace junction box.

7 Flashes

High Limit Switch Open

Overheating detected. Limit switch tripped due to restricted airflow or failed blower.

DIY check: Check air filter, supply registers, blower wheel, and blower motor.

Common part needed: Shop Fan Motor →

8 Flashes

Low Flame at 2nd Stage

On two-stage furnaces, the flame signal drops below acceptable when switching to high fire.

DIY check: Clean flame sensor. Check gas pressure at both stages. May need gas valve adjustment (technician).

Common part needed: Shop Flame Sensor →

9 Flashes

Gas Valve Relay Error

The gas valve relay on the control board has failed or the valve circuit is open.

DIY check: Check gas valve wiring. Test the gas valve coil. If the relay on the board has failed, the board needs replacement.

Common part needed: Shop Gas Valve →

10 Flashes

Blower Motor Fault

The blower motor did not reach the expected speed or failed to start.

DIY check: Check blower motor, run capacitor, and wiring. On ECM motors, check the motor module.

Common part needed: Shop Fan Motor →

11 Flashes

Flame Without Call for Heat

Flame detected without a thermostat demand. The gas valve may be leaking.

DIY check: Turn off furnace and gas immediately. Call a technician.

Common part needed: Shop Gas Valve →

12 Flashes

Flame Lost During Run

The flame was established but then lost during the heating cycle. Different from Code 5 (weak signal) - here the signal dropped to zero.

DIY check: Check gas supply pressure (may be intermittent). Clean flame sensor. Check for drafts or wind affecting the burner flame.

Common part needed: Shop Flame Sensor →

13 Flashes

Communication Error

Communication fault between the control board and an accessory or communicating thermostat.

DIY check: Check thermostat wiring. Verify the thermostat is compatible with the furnace. Check for damaged wires.

14 Flashes

Power Interrupted to Board

The control detected a momentary power loss that did not fully reset the board. May cause erratic behavior.

DIY check: Check for loose wiring connections at the furnace. Ensure the circuit breaker and switch connections are tight.

When to call a technician

If the same code keeps coming back after you have addressed the obvious cause (dirty filter, flame sensor, etc.), or if you smell gas, see burn marks, or the furnace will not come out of lockout after a power cycle, call a licensed HVAC technician. Electrical and gas work carries real safety risk.

FAQ

How do I reset my Ruud furnace after an error code?
Turn the furnace power off at the switch or breaker for 30 seconds, then turn it back on. The control board will clear the lockout and attempt to restart. If the same code returns, the underlying problem has not been fixed.
My Ruud furnace shows no LED light at all
No light means no power to the control board. Check: the furnace switch is on, the breaker is not tripped, and the door safety switch is engaged (the furnace door must be fully closed). If all three check out, the control board or transformer may have failed.
Can I fix Ruud error codes myself?
Many codes point to simple fixes: replacing a dirty filter (codes related to overheating), cleaning the flame sensor (codes related to flame proving), or clearing a blocked condensate drain (pressure switch codes). Anything involving gas lines, wiring, or the heat exchanger should be left to a licensed technician.
Need HVAC parts?
15,000+ OEM parts with same-day shipping. Find parts by model or diagnose your system.