Same-day shipping on orders before 3PM CST · 10,893 OEM Parts In Stock · Carrier · Bryant · ICP · Heil · Tempstar

Menu

Home Shop All Account Cart

Luxaire Furnace Error Codes - Complete Guide

Luxaire furnaces are manufactured by Johnson Controls along with York and Coleman. All three brands use a RED LED flash code system. Green = normal, red = fault. Also covers York, Coleman.

All Luxaire Error Codes

1 red flash
York 1 Red Flash — Flame Sensed With Gas Valve Closed
Flame detected when gas valve closed — leaky valve.
2 red flashes
York 2 Red Flashes — Pressure Switch Stuck Closed
Pressure switch stuck closed.
3 red flashes
York 3 Red Flashes — Pressure Switch Stuck Open
Pressure switch open during inducer operation.
4 red flashes
York 4 Red Flashes — Limit Switch Open
Limit switch open — overheating. Usually restricted airflow.
5 red flashes
York 5 Red Flashes — Roll Out Switch Open (SAFETY)
Flame rollout switch tripped — possible cracked heat exchanger and CO risk.
6 red flashes
York 6 Red Flashes — Locked Out on Pressure Switch Error
Pressure switch lockout after persistent errors.
7 red flashes
York 7 Red Flashes — Ignition Lockout
Locked out after too many ignition attempts.
8 red flashes
York 8 Red Flashes — Locked Out on Repeated Power Cycles
Locked out due to frequent power cycling.
9 red flashes
York 9 Red Flashes — Grounding or Polarity Issue
Grounding or polarity issue — wiring fault.
10 red flashes
York 10 Red Flashes — Gas Flows With Valve Closed
Gas continues to flow when valve should be closed — faulty valve.
11 red flashes
York 11 Red Flashes — Limit Open Over 5 Minutes
Limit switch open more than 5 minutes — usually failed blower.
12 red flashes
York 12 Red Flashes — Open Igniter Circuit
Open igniter circuit — failed igniter or wiring fault.

Need Help With Something Else?

If you don't see your code here, try our master error code lookup covering all major brands, or our symptom-based diagnostic tool.

Browse Luxaire parts inventory.

Home Shop Search Account Cart