MEDIUM URGENCY
Trane Furnace 9 Flashes — Igniter Problem
9 flashes
Igniter fault — usually a failed hot surface igniter.
Brand: Trane (Also covers American Standard) | Equipment: Gas Furnace
SAFETY: Hot surface igniters are fragile — handle by the ceramic body, not the silicon-carbide element.
What This Code Means
9 flashes means the control detects an issue with the hot surface igniter. Either it failed to heat up, drew abnormal current, or shows an open circuit.
Likely Causes (Ranked)
Most common
Cracked or burned-out igniter
What: Igniter element is broken or burned through.
How to check: Cut power; visually inspect igniter for cracks.
Fix: Replace igniter.
Shop parts
Common
Igniter wiring issue
What: Loose or broken wire to the igniter.
How to check: Inspect wires at igniter and board.
Fix: Repair connection.
Less common
Bad control board
What: Board can't drive igniter properly.
How to check: Tech diagnostic.
Fix: Replace board.
Shop parts
Diagnostic Steps
- Cut power and visually inspect igniter
- Check wiring at igniter and board
- Replace igniter if cracked
- Call tech if both look OK
Frequently Asked Questions
How long does a Trane igniter last?
Typical lifespan is 3-5 years.
Can I replace it myself?
Yes — usually 2 wire connections and 1-2 mounting screws.
Same on American Standard?
Yes.
Related Trane Codes
Related Symptoms
Need More Help?
Try our interactive symptom diagnostic tool or browse Trane parts.