One-hour soft lockout after repeated ignition failures.
Brand: Rheem (Also covers Ruud) | Equipment: Gas Furnace
Code 10 on a Rheem furnace (also Ruud) means the control entered a 1-hour soft lockout after multiple failed ignition attempts. The furnace will retry automatically after 60 minutes, but the underlying issue must be fixed or it will lock out again.
What: Coated sensor can't detect flame; control thinks ignition failed.
How to check: Pull and inspect for soot.
Fix: Clean with fine emery cloth.
Shop partsWhat: Igniter not reaching ignition temperature.
How to check: Watch for orange glow.
Fix: Replace igniter.
Shop partsWhat: Closed valve or low pressure.
How to check: Verify gas valve open; test other appliances.
Fix: Open valve or call gas utility.
Try our interactive symptom diagnostic tool or browse Rheem parts.