MEDIUM URGENCY
Carrier Code 43 - Pressure Switch Calibration Faulty
Code 43 (4 short + 3 long flashes)
Pressure switch calibration fault.
Brand: Carrier (Also covers Bryant, Payne) | Equipment: Gas Furnace
What This Code Means
Code 43 on Carrier (Bryant, Payne) means the pressure switch is reading values outside its expected calibration range. Usually obstruction or switch degradation.
Likely Causes (Ranked)
Most common on 90%+ AFUE
Blocked condensate trap
What: Plugged condensate drain affects pressure readings.
How to check: Inspect condensate trap and drain.
Fix: Clear trap, flush drain line.
Common
Blocked intake or exhaust
What: Restricted venting affects pressure.
How to check: Inspect both intake and exhaust outlets.
Fix: Clear blockages.
Shop parts
Common
Failing pressure switch
What: Switch is degrading, readings drift.
How to check: Tech manometer test.
Fix: Replace switch.
Shop parts
Diagnostic Steps
- Inspect intake and exhaust
- Check condensate trap
- Replace pressure switch if obstructions cleared
- Call tech if persistent
Frequently Asked Questions
Difference between Carrier code 23, 31, 43?
23/31 are pressure switch on/off faults; 43 is calibration drift (switch operating but values off).
Same on Bryant/Payne?
Yes - identical control board.
DIY?
Vent and trap inspection yes; switch replacement straightforward.
Related Carrier Codes
Related Symptoms
Need More Help?
Try our interactive symptom diagnostic tool or browse Carrier parts.