The Goodman 10135604 Relay is a genuine OEM electromechanical relay built for the ASZ130361AB heat pump. It handles the load-switching duty between the low-voltage control signal and the line-voltage components, and a failed relay is a common cause of a unit that won't start, chatters, or drops out under load.
OEM relays are rated for the exact inductive load and duty cycle of the ASZ130361AB circuit. A generic relay may carry a lower contact rating, leading to welded contacts or premature failure under repeated compressor/blower cycling. The OEM part drops into the existing terminals with no adapter wiring, preserving factory reliability.
Easy (2/5). Kill power at the disconnect, photograph and label the terminal connections, unplug or unscrew the old relay, and transfer wires one at a time to the identical terminals. 15–20 minutes with a nut driver and needle-nose pliers. Confirm coil voltage matches before energizing.