IMAGE COMING SOON
OEM Guaranteed
Same-Day Ship
30-Day Returns
Secure Checkout
The Goodman 0130F00036 is a genuine OEM primary high-limit switch (identified by its pink housing) engineered for the Goodman ACVC800803BXAB two-stage variable-speed gas furnace. This thermally activated safety control monitors heat-exchanger and plenum temperatures, automatically opening the circuit to shut down the burners if the furnace overheats — protecting the heat exchanger, blower, and your home from dangerous high-temperature conditions.
The factory-specified OEM switch is calibrated to the exact trip temperature your furnace board expects. Generic substitutes may trip early (nuisance lockouts) or late (insufficient protection). For a safety-critical limit control, OEM is strongly recommended.
Easy (2/5). A two-wire spade-terminal swap that most handy homeowners can complete in 10–15 minutes. Always cut power at the furnace disconnect before servicing. If you are unsure why the original limit tripped, have a licensed HVAC technician inspect for airflow restrictions first.