IMAGE COMING SOON
OEM Guaranteed
Same-Day Ship
30-Day Returns
Secure Checkout
The Goodman 0130F00070 is a genuine OEM air pressure switch for the ACVM960604CXAA gas furnace and compatible Goodman/Amana models. It proves that the inducer (draft) motor is pulling adequate negative pressure before allowing ignition. If venting is blocked, the condensate trap is clogged, or the inducer is weak, the switch keeps the gas valve closed — a critical safety interlock against flue-gas spillage.
Pressure switches are rated to a precise actuation point (inches of water column). The genuine Goodman OEM switch carries the exact setpoint for this furnace, so it proves draft correctly. A generic switch with a mismatched rating commonly causes "pressure switch open" lockouts even when venting is fine. OEM is the recommended fit.
Moderate (3/5). Cut power, photograph and transfer the hose(s) and wiring, then swap the switch on its bracket. About 20–30 minutes. Verify the W.C. rating on the new switch matches the original before powering up.