IMAGE COMING SOON
OEM Guaranteed
Same-Day Ship
30-Day Returns
Secure Checkout
The Goodman 0130F00070 Pressure Switch is a genuine OEM safety control for the Goodman ACVC950915DXAC condensing gas furnace. The pressure switch confirms that the inducer (draft) motor is producing adequate negative pressure and that the venting and condensate paths are clear before the control board allows ignition. A failed switch — or a blocked vent/drain — produces the common "pressure switch open" or "failed to close" lockout.
Pressure switches are calibrated to a specific trip point measured in inches of water column ("WC). The genuine OEM 0130F00070 is set to the exact pressure the ACVC95 platform requires. A generic switch with a different setpoint can refuse to close on a healthy system or fail to detect a true venting fault.
Easy (2/5). Power off, remove the hose and spade terminals, unscrew the switch, and install the matching part. Confirm the pressure rating before reconnecting. If the new switch still won't close, inspect the vent, drain, and inducer for blockage.