IMAGE COMING SOON
OEM Guaranteed
Same-Day Ship
30-Day Returns
Secure Checkout
The Goodman 0130F00070 is a genuine OEM air pressure switch for the ACVC950714CXBA condensing gas furnace and compatible Goodman/Amana models. The pressure switch proves that the inducer (draft) motor has created adequate negative pressure to safely vent combustion gases before the control board allows ignition. If it doesn't sense the correct draft — due to a weak inducer, blocked vent, plugged condensate trap, or cracked hose — it keeps the gas valve closed and the furnace will not fire, often throwing a pressure-switch fault (e.g., Code 31) or going into lockout.
Pressure switches are matched to an exact set point (measured in inches of water column). The genuine OEM 0130F00070 carries the correct trip pressure and port configuration for this furnace. A generic switch with the wrong set point can either nuisance-trip on a healthy unit or fail to protect against a genuine venting problem — both unacceptable on a combustion safety.
Easy (2 of 5). Around 15 minutes. Cut power, photograph and transfer the wires and the rubber sensing hose to the new switch, then mount it. Confirm the hose is clear and the trap is clean so the new switch isn't fighting a real draft problem. Verify model/serial compatibility before installing.