The Goodman 11177113 Combination Pressure Switch is a genuine OEM dual air-proving safety control for the Amana AMVC950704CXAD two-stage, high-efficiency gas furnace. This gray combination switch verifies proper draft on both the low-fire (-.30 in. WC) and high-fire (-.75 in. WC) stages before allowing the ignition sequence, protecting against blocked vents, condensate backup, and inducer failure.
Pressure switch setpoints are calibrated to this furnace's inducer and venting design. The OEM 11177113 carries both factory-calibrated setpoints in one gray body. Generic switches with slightly different trip points can cause intermittent no-heat lockouts or, worse, allow operation under unsafe draft conditions. For a safety control, genuine OEM calibration is non-negotiable.
Moderate (3 of 5). Involves matching the hose ports correctly, transferring wiring, and confirming the switch closes on a draft test. A multimeter and manometer help verify operation. Recommended for HVAC technicians. Always shut off power and gas before servicing.