IMAGE COMING SOON
OEM Guaranteed
Same-Day Ship
30-Day Returns
Secure Checkout
The Goodman 10123519 is a genuine OEM manual reset limit switch (thermal rollout / high-limit safety) for the AMH951155DXAD gas furnace. This normally-closed switch monitors temperature at the burner or heat exchanger and opens the control circuit if it detects an overheat or flame rollout condition, shutting down the furnace to prevent damage or a fire hazard. Because it is a manual reset design, it stays open after a fault until the technician presses the reset button — a deliberate safety feature that flags an underlying problem.
Safety limit switches are calibrated to a specific trip temperature. A generic switch with the wrong setpoint may nuisance-trip or, dangerously, fail to trip when needed. This OEM switch carries the exact temperature rating and terminal configuration the AMH951155DXAD control board expects, preserving the furnace's built-in safety response.
Easy–Moderate (2/5) — Roughly a 15–20 minute repair. Cut power to the furnace, note and disconnect the wire terminals, unscrew the old switch, and mount the replacement in the same orientation. If the switch had tripped, diagnose the root cause (blocked airflow, dirty burners, cracked heat exchanger) before returning the unit to service.