IMAGE COMING SOON
OEM Guaranteed
Same-Day Ship
30-Day Returns
Secure Checkout
The Goodman 10123529 is a genuine OEM manual reset high-limit switch designed for DMP100-42AA gas furnaces and compatible Goodman/Amana models. This safety-critical component monitors furnace temperature and cuts power to the gas valve when it senses dangerous overheating — protecting the heat exchanger, wiring, and cabinet from heat damage. Because it is a manual reset switch, it must be pressed to restore operation after a trip, prompting the homeowner or technician to investigate the root cause (dirty filter, blocked airflow, or failing blower).
The OEM Goodman 10123529 is calibrated to the exact trip temperature your furnace's control board and heat exchanger expect. Generic limit switches with the wrong set-point may trip early (nuisance shutdowns) or, worse, trip late — defeating the safety purpose. For any furnace safety control, genuine OEM is the responsible choice.
Easy. The switch mounts with two screws and two spade connectors. Allow 15–20 minutes. Shut off power at the breaker before servicing. If the switch trips again after reset, have the furnace inspected — a repeat trip signals an airflow or heat-exchanger problem.